Belden 3082A T5U DeviceBus 2 Prs 15+18 AWG TC Gray

Belden 3082A

SKU:Belden 3082A T5U

$485.00

En stock

Description

Spécifications

Belden 3082A T5U DeviceBus 2 Prs 15+18 AWG TC Gray specifications
AttributeValue
Conductor count2 PAIRS
Power pair(s)1 pair, 15 AWG, 19x27, TC - Tinned Copper
Data pair(s)1 pair, 18 AWG, 19x30, TC - Tinned Copper
Conductor TypeStranded Conductor
Power pair insulationPVC - Polyvinyl Chloride, 0.021 in (0.53 mm) nominal thickness, 0.109 in (2.77 mm) nominal Insulation Diameter, Red & Black
Data pair insulationPE - Polyethylene (Foam), 0.053 in (1.3 mm) nominal thickness, 0.150 in (3.81 mm) nominal Insulation Diameter, Blue & White, HDPE
Shield constructionIndividual & Overall Braid Shield
Inner shield (power pair(s))Tape, Bi-Laminate (Alum+Poly), 100% coverage
Inner shield (data pair(s))Tape, Bi-Laminate (Alum+Poly), 100% coverage
Outer shieldBraid, Tinned Copper (TC), 65% coverage
Jacket MaterialPVC - Polyvinyl Chloride
Outer jacketPVC - Polyvinyl Chloride, 0.060 in (1.5 mm) nominal thickness
Overall cable diameter (nominal)0.480 in (12.2 mm)
Outer jacket nominal diameter0.480 in (12.2 mm)
Jacket OD +/-+/- 0.010
Bulk cable weight128 lbs/1000ft
Power pair(s) nominal Conductor DCR3.58 Ohm/1000ft
Power pair(s) nominal inner Shield DCR5.75 Ohm/1000ft (18.9 Ohm/km)
Power pair(s) nominal inductance0.174 µH/ft (0.571 µH/m)
Power pair(s) max. current16 Amps per Conductor at 30ºC
Data pair(s) nominal Conductor DCR7.2 Ohm/1000ft (24 Ohm/km)
Data pair(s) nominal inner Shield DCR3.58 Ohm/1000ft (11.7 Ohm/km)
Data pair(s) nominal capacitance Cond-to-Cond12 pF/ft (39 pF/m)
Data pair(s) nominal characteristic impedence120 Ohm
Data pair(s) nominal delay1.36 ns/ft
Data pair(s) nominal velocity of prop.75%
Data pair(s) max. current14 Amps per Conductor at 30ºC
Nom. outer shield DCR7.29 Ohm/1000ft (23.9 Ohm/km)
Voltage Rating300 V (AWM I/II A)
UL temperature60°C
Bend radius (stationary min.)5.76 in (146 mm)
Bend radius (installation min.)5.76 in (146 mm)
Max Pull Tension192.6 lbs (87.36 kg)
NEC / UL complianceArticle 725, Article 800, CMG, PLTC
AWM complianceAWM 20201, AWM I/II A
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL 1685 FT4 Loading, IEEE 1202 FT4, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)ODVA Class 2 Thick
Item TypeBelden Multi Conductor Cable
Other Part Numbers3082A T5U, 3082A T5U100, 3082A T5U250, 3082A T5U500, 3082A T5U1000
Priced PerFT

Documents

Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.

Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?