Belden 3095A F2V ControlBus Coaxial RG11 14 AWG BCCS Gaine FEP PVDF specifications
AttributeValue
Coax constructionCoax RG11
RG type11
Number of coax1
Number of Conductors1
Conductor nominal diameter0.064 in
Insulation nominal diameter0.28 in
Jacket nominal diameter0.387 in
Nominal characteristic impedance100 Ohm
Nominal characteristic tolerance± 3 Ohm
Nom. capacitance (Conductor to Shield)16.5 pF/ft
Nominal inductance0.097 µH/ft
Nominal delay1.2 ns/ft
Nominal velocity of propagation (VP) [%]82%
UL Voltage Rating300 V RMS
Nominal conductor DCR11 Ohm/1000ft
Nominal outer shield DCR3.9 Ohm/1000ft
Outer conductor DCR3.9 Ohm/1000ft
Insertion loss @ 1 MHz0.17 dB/100ft
Insertion loss @ 2 MHz0.22 dB/100ft
Insertion loss 5 MHz0.28 dB/100ft
Insertion loss @ 10 MHz0.4 dB/100ft
Insertion loss @ 20 MHz0.6 dB/100ft
Insertion loss @ 50 MHz1.2 dB/100ft
Insertion loss @ 100 MHz1.7 dB/100ft
Insertion loss @ 200 MHz2.5 dB/100ft
Insertion loss @ 300 MHz3.04 dB/100ft
Insertion loss @ 400 MHz3.5 dB/100ft
Phase delay distortion f/B 0.5-0.6
Phase delay distortion f/B 1-0.46
Phase delay distortion f/B 1.50
Phase delay distortion f/B 20.17
Phase delay distortion f/B 2.50.3
Structural return loss @ 1 MHz20 dB
Tilt 5 to 10 MHz.42 dB/100 M
Tilt 10 to 20 MHz.58 dB/100 M
SLRSLR Min. 20dB (5MHz - 50MHz)
UL Temperature Rating150°C
Operating Temperature Range-20°C To +150°C
Bulk cable weight68 lbs/1000ft
Maximum recommended pulling tension309 lbs
Minimum minor axis bend radius4 in
NEC articlesArticle 800
NEC / UL complianceCMP
CEC / C(UL) complianceCMP
UL flammabilityNFPA 262
CSA flammabilityFT6
EU Directive 2000/53/EC (ELV)Yes
EU Directive 2011/65/EU (RoHS 2)Yes
EU Directive 2012/19/EU (WEEE)Yes
EU Directive 2015/863/EU (RoHS 2 amendment)Yes
EU directive complianceEU Directive 2003/11/EC (BFR)
MII Order #39 (China RoHS)Yes
Suitability - burialYes
Suitability - OutdoorYes
Non-Plenum number3094A
Item TypeBelden Coaxial Cable RG11
Other Part Numbers3095A F2V, 3095A F2V100, 3095A F2V250, 3095A F2V500, 3095A F2V1000
Priced PerFT

Documents

Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.

Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?

Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.