Belden 6202UE 877 is a Security & Sound Cable, Plenum-CMP, designed for indoor plenum installations. It features 4 stranded 16 AWG BC - Bare Copper conductors with Flamarrest® insulation and a Flamarrest® jacket, plus a ripcord for easier stripping. Rated 300 V, it meets NFPA 262 and UL 910 (Plenum). Sequential footage marking every two feet helps speed pulls and supports accurate cut lengths.
Key Features
- Plenum-rated construction: Security & Sound Cable, Plenum-CMP for indoor plenum spaces.
- 4 stranded 16 AWG conductors made from BC - Bare Copper for signal and power delivery.
- Flamarrest® insulation and Flamarrest® jacket to support plenum fire performance requirements.
- Ripcord included to simplify jacket removal during installation.
- Sequential footage marking every two feet to support measuring and cutting to length.
Technical Specs
Construction & Materials
| Number of conductors | 4 |
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Insulation nominal thickness | 0.008 in (0.20 mm) |
| Insulation nominal diameter | 0.073 in (1.9 mm) |
| Insulation color code | Black, Red, White, Green |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Outer jacket nominal thickness | 0.015 in (0.38 mm) |
Electrical & Performance Characteristics
| UL voltage rating | 300 V |
| Nominal conductor DCR | 3.8 Ohm/1000ft |
| Nominal capacitance (cond-to-cond) | 36.5 pF/ft (120 pF/m) |
| Max. current | 14.4 Amps per Conductor @ 25°C |
Physical Dimensions & Weight
| Outer jacket nominal diameter | 0.206 in (5.23 mm) |
| Overall cable diameter (nominal) | 0.206 in (5.23 mm) |
| Bulk cable weight | 43 lbs/1000ft |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.0 in (51 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max. pull tension | 160 lbs (73 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
Related Part Information
Applications
- Use in security system installations where plenum-rated cabling is required.
- Run intercom/PA lines in indoor plenum spaces for building communications.
- Support audio/speaker wiring where consistent identification and measured pulls are helpful.
- Install for power-limited controls in indoor plenum environments that call for CMP compliance.
Belden™ and all associated trademarks are the property of their respective owners.