Belden 6300FE 008U, Multi Conductor Cable 2C 18 Stranded FOIL SHD FRPVC

SKU:Belden 6300FE 008U
● En stock
Description
Belden 6300FE 008U is a Plenum-CMP Security & Commercial Audio Cable with 2 conductors of 18 AWG stranded BC - Bare Copper. It features PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride jacket with ripcord, along with a tape shield with 100% coverage and a 24 AWG (7x32) TC drainwire. Designed for indoor plenum installations, it is rated 300 V and meets NFPA 262 and Article 800, CMP.
Key Features
- Plenum-CMP fire rating for indoor plenum installations.
- 2 x 18 AWG stranded BC - Bare Copper conductors (7x26) for security and commercial audio wiring.
- PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride jacket with ripcord for easier pulls and handling.
- Tape shield with 100% coverage and Bi-Laminate (Alum+Poly) shield material, plus a 24 AWG (7x32) TC drainwire.
- 0.162 in (4.11 mm) nominal overall cable diameter for routing in tighter pathways.
Technical Specs
Construction & Materials
| Cable type | Security & Commercial Audio Cable |
|---|---|
| Number of conductors | 2 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Color code | Black, Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Ripcord | Yes |
Performance & Electrical Characteristics
| UL voltage rating | 300 V |
|---|---|
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance (cond-to-cond) | 70 pF/ft (230 pF/m) |
| Nom. capacitance (cond-to-other) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 14 Amps per conductor @ 25°C |
| Nom outer shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max. pull tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|---|
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-Plenum number | 5300FH |
|---|
Applications
- Use in security system installations where a plenum-rated cable is required.
- Run intercom/PA wiring through indoor building pathways.
- Support audio/speaker connections that benefit from an overall shield and drainwire.
- Install in noisy environments where shielding helps manage interference.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Cable type | Security & Commercial Audio Cable |
| Number of Conductors | 2 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Color Code | Black, Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Ripcord | Yes |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 70 pF/ft (230 pF/m) |
| Nom. capacitance (Cond-to-other) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 14 Amps per conductor @ 25°C |
| Nom. outer shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.6 in (41 mm) |
| Bend radius (installation min.) | 1.6 in (41 mm) |
| Max Pull Tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
| Environmental suitability | Indoor - Plenum, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |