Belden 6502FE 010A, 22 AWG 4C Foil Shield LSPVC Black 1000’ Box

SKU:Belden 6502FE 010A
● En stock
Description
Belden 6502FE 010A is a Security & Sound Cable with a Plenum-CMP rating for indoor plenum installations. It features 4 stranded 22 AWG BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation, along with a tape shield with 100% coverage and a 24 AWG (7x32) TC drainwire. The cable is finished with a PVC - Polyvinyl Chloride jacket and includes a ripcord for easier handling. Electrical ratings include a UL Voltage Rating of 300 V (CMP) and a UL temperature of 75°C.
Key Features
- Plenum-CMP rated Security & Sound Cable for indoor plenum installations.
- 4 stranded 22 AWG BC - Bare Copper conductors with color code: Black, Red, White, Green.
- Tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage, plus a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket with ripcord: Yes.
- UL Voltage Rating: 300 V (CMP); UL temperature: 75°C.
Technical Specs
Construction & Materials
| Cable Type | Security & Sound Cable |
|---|---|
| Environmental suitability | Indoor - Plenum, Indoor |
| Number of conductors | 4 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. thickness (Insulation) | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.047 in (1.2 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (Jacket) | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.147 in (3.73 mm) |
| Non-Plenum number | 5502FE |
Performance & Electrical Characteristics
| Nom. conductor DCR | 16.2 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-Cond | 33.0 pF/ft (108 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 59 pF/ft (190 pF/m) |
| Max. current | 2.2 Amps per Conductor at 25ºC |
| Nom outer Shield DCR | 18.38 Ohm/1000ft (60.30 Ohm/km) |
Environmental & Mechanical Ratings
| Operating temperature | 0°C to +75°C |
|---|---|
| Bend radius (stationary min.) | 1.47 in (37.3 mm) |
| Bend radius (installation min.) | 1.47 in (37.3 mm) |
| Max. pull tension | 42 lbs (19 kg) |
| Bulk cable weight | 17 lbs/1000ft |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Supports security system wiring in indoor plenum spaces where CMP cable is required.
- Use it for intercom/PA connections in building interiors.
- Run it for audio/speaker connections in installed low-voltage systems.
- Apply it to power-limited controls where a shielded construction is used.
- Choose it for noisy environment installations where shielding is needed.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Cable type | Security & Sound Cable |
| Environmental suitability | Indoor - Plenum, Indoor |
| Number of Conductors | 4 |
| Conductor size | 22 AWG |
| Conductor stranding | 7x30 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. thickness (insulation) | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.047 in (1.2 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 24 AWG (7x32) TC |
| Jacket Material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.147 in (3.73 mm) |
| Non-Plenum number | 5502FE |
| Nom. conductor DCR | 16.2 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 33.0 pF/ft (108 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 59 pF/ft (190 pF/m) |
| Max. current | 2.2 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 18.38 Ohm/1000ft (60.30 Ohm/km) |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 1.47 in (37.3 mm) |
| Bend radius (installation min.) | 1.47 in (37.3 mm) |
| Max Pull Tension | 42 lbs (19 kg) |
| Bulk cable weight | 17 lbs/1000ft |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?