Belden 6545FE 877 is a Plenum-CMP security & sound cable built with 6 pairs of 22 AWG stranded bare copper conductors and a PVC - Polyvinyl Chloride jacket. It uses a 100% tape shield made from Bi-Laminate (Alum+Poly) with a 24 AWG (7x32) TC drainwire type, and includes a ripcord for easier stripping. Key electrical characteristics include a UL Voltage Rating of 300 V, a Nom. Conductor DCR of 17.5 Ohm/1000ft, and a Max. current of 2 Amps per Conductor at 25ºC.
Key Features
- Plenum-CMP security & sound cable design for indoor installations.
- 6 pairs of 22 AWG stranded bare copper conductors with 7x30 stranding.
- 100% tape shield using Bi-Laminate (Alum+Poly) with a 24 AWG (7x32) TC drainwire type.
- PVC - Polyvinyl Chloride insulation and PVC - Polyvinyl Chloride jacket.
- Includes a ripcord to help speed up stripping and installation.
- UL Voltage Rating: 300 V; Max. current: 2 Amps per Conductor at 25ºC.
Technical Specs
Construction & Materials
| Elements | pair(s) |
| Number of elements | 6 |
| Conductor Size | 22 |
| Conductor Material | BC - Bare Copper |
| Insulation thickness | 0.009 in (0.23 mm) |
| Nom. Insulation Diameter | 0.047 in (1.2 mm) |
| Color code | Black & Red, Black & White, Black & Green, Black & Blue, Black & Yellow, Black & Brown |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Jacket thickness | 0.015 in (0.38 mm) |
| Nom. Diameter | 0.268 in |
Electrical Characteristics
| Nom Outer Shield DCR | 12.7 Ohm/1000ft (41.7 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 33 pF/ft (110 pF/m) |
| Nom. capacitance Cond-to-other (Conds + Shield) | 59.4 pF/ft (195 pF/m) |
| Nom. inductance | 0.18 μH/ft (0.59 μH/m) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend Radius (stationary min.) | 2.68 in (68.1 mm) |
| Bend Radius (installation min.) | 2.68 in |
| Max. pull tension | 114.6 lbs (51.98 kg) |
| Bulk Cable Weight | 46.1 lbs/1000ft |
| Environmental suitability | Indoor |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262 (UL910), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Identification & Reference
| Non-Plenum number | 5545FE |
| Footage marking | Sequential footage marking every two feet |
Applications
- Designed for security system wiring in indoor environments.
- Use it for intercom/PA installations where paired conductors are needed for signal distribution.
- Choose it for audio/speaker runs in noisy environments where shielding is beneficial.
- Intended for power-limited control applications in indoor settings.
- Well-suited for noisy environment installations where improved noise rejection is desired.
Belden™ and all associated trademarks are the property of their respective owners.