Belden 735A1 008 is a 75 Ohm coax cable with a 26 AWG solid 0.016 in SCCS - Silvered Copper Covered Steel center conductor and PE - Polyethylene (Foam) insulation. It features dual-layer shielding with Beldfoil® tape and a Tinned Copper braid, and a PVC - Polyvinyl Chloride jacket in Gray. Designed for indoor - riser installations, it meets NEC/(UL) Compliance: CMR and CEC/C(UL) Compliance: CMG and has a UL Voltage Rating of 300 V RMS.
Belden 735A1 008 Key Features
- 75 Ohm nominal characteristic impedance for coax signal transmission.
- 26 AWG solid 0.016 in SCCS - Silvered Copper Covered Steel center conductor.
- PE - Polyethylene (Foam) insulation with 0.077 in nominal diameter.
- Dual-layer shielding: Beldfoil® tape (100% coverage) plus Tinned Copper (TC) braid (95% coverage).
- PVC - Polyvinyl Chloride jacket in Gray with 0.129 in nominal diameter.
- Environmental Space: indoor - riser.
- NEC/(UL) Compliance: CMR and CEC/C(UL) Compliance: CMG.
- UL Voltage Rating: 300 V RMS.
Belden 735A1 008 Technical Specs
Construction & Type
| Type | 735 |
| RG Type | Mini 59 |
| Number Of Conductors | 1 |
| No. of Coax | 1 |
Electrical Characteristics
| Nom. Capacitance Conductor to Shield | 17.7 pF/ft |
| Nominal Inductance | 0.19 μH/ft |
| Nominal Delay | 1.34 ns/ft |
| Nominal Velocity of Propagation (VP) [%] | 76% |
| Nominal Conductor DCR | 41 Ohm/1000ft |
| Nominal Outer Shield DCR | 5.3 Ohm/1000ft |
Performance (Return Loss & Attenuation)
| Return Loss Frequency [MHz] | 15-90 dB |
| Minimum Return (RL) | 30 dB |
| Max. Insertion Loss (Attenuation) @ 1 MHz | 0.6 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 1.024 MHz | 0.61 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 4.224 MHz | 1.1 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 5 MHz | 1.2 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 10 MHz | 1.7 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 17.184 MHz | 2.2 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 22.368 MHz | 2.5 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 25.92 MHz | 2.7 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 44.736 MHz | 3.6 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 50 MHz | 3.8 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 69.632 MHz | 4.5 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 77.76 MHz | 4.8 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 100 MHz | 5.5 dB/100ft |
| Max. Insertion Loss (Attenuation) @ 200 MHz | 7.8 dB/100ft |
Environmental & Mechanical Ratings
| Operating Temperature Range | -40°C To +75°C |
| Bulk Cable Weight | 12 lbs/1000ft |
| Maximum Recommended Pulling Tension | 25 lbs |
| Minimum Minor Axis Bend Radius | 1.25 in |
| Suitability - Indoor | Yes |
| Plenum (Y/N) | No |
| Plenum Number | 735A1P |
Compliance & Certifications
| CPR Euroclass | Eca |
| UL Flammability | UL1666 Vertical Shaft |
| CSA Flammability | FT4 |
| IEC Flammability | IEC 60332-1-2 |
| EU Directive 2000/53/EC (ELV) | Yes |
| EU Directive 2003/11/EC (BFR) | Yes |
| EU Directive 2011/65/EU (RoHS 2) | Yes |
| EU Directive 2012/19/EU (WEEE) | Yes |
| EU Directive 2015/863/EU (RoHS 2 amendment) | Yes |
| EU Directive Compliance | EU Directive 2003/11/EC (BFR) |
| EU CE Mark | Yes |
| MII Order #39 (China RoHS) | Yes |
Belden 735A1 008 Applications
- Use in indoor - riser installations where consistent signal performance is required.
- Support indoor building cable runs that require NEC/(UL) Compliance: CMR and CEC/C(UL) Compliance: CMG.
- Choose for indoor use where shielding with Beldfoil® tape and a Tinned Copper braid is desired for noise rejection.