Contact1-800-975-3686
Ramcorp Wire & Cable

Belden 7895A T5U DeviceBus pour ODVA 2 18 AWG PVC

Belden 7895A T5U

SKU:Belden 7895A T5U

$814.80

En stock

Description

Spécifications

Belden 7895A T5U DeviceBus pour ODVA 2 18 AWG PVC specifications
AttributeValue
Power pair1 pair, 18 AWG, 19x30, TC - Tinned Copper
Data pair1 pair, 20 AWG, 19x32, TC - Tinned Copper
Conductor TypeStranded conductor
Power pair insulationPVC - Polyvinyl Chloride, 0.018 in (0.46 mm) nominal thickness, 0.080 in (2.0 mm) nominal insulation diameter, Red & Black
Data pair insulationPE - Polyethylene (Foam), 0.040 in (1.0 mm) nominal thickness, 0.129 in (3.28 mm) nominal insulation diameter, Blue & White
Inner shield (power pair)Tape, Bi-Laminate (Alum+Poly), 100%
Inner shield (data pair)Tape, Bi-Laminate (Alum+Poly), 100%
Shield constructionOverall & individual shields w/drain
Outer jacket materialPVC - Polyvinyl Chloride
Nom. jacket thickness0.045 in (1.1 mm)
Nom. diameter0.378 in (9.60 mm)
Overall cable diameter (nominal)0.378 in (9.60 mm)
Jacket OD +/-0.010
Bulk cable weight76 lbs/1000ft
Power pair nominal conductor DCR6.9 Ohm/1000ft
Power pair max. conductor DCR6.9 Ohm/1000ft
Max. current (power pair)4 Amps Per Conductor at 24 V (per NEC CL2) (Power Pair)
Data pair nominal conductor DCR10.9 Ohm/1000ft (35.8 Ohm/km)
Data pair max. conductor DCR10.9 Ohm/100m
Data pair nominal capacitance (Cond-to-Cond)12 pF/ft (39 pF/m)
Data pair nominal characteristic impedence120 Ohm
Data pair nominal velocity of prop.75%
Nom. outer shield DCR3.2 Ohm/1000ft (10 Ohm/km)
UL temperature75°C
Operating temperature-20°C to +75°C
Bend radius (stationary min.)3.8 in (97 mm)
Bend radius (installation min.)3.8 in (97 mm)
Max Pull Tension65 lbs (29 kg)
Environmental suitabilityIndoor, Outdoor, Sunlight Resistance, Oil Resistance
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, IEEE 1202, IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
NEC / UL complianceArticle 725, Article 800, CMG, PLTC
AWM complianceAWM 20201
CEC / C(UL) complianceCMG
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
Other standard compliance(s)ODVA Cable III
Item TypeBelden Multi Conductor Cable
Other Part Numbers7895A T5U100, 7895A T5U250, 7895A T5U500, 7895A T5U1000
Priced PerFT

Documents

Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.

Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?

Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.