Belden 8641 060, Multi Pair Cable 1C 24 AWG PE PVC Jacket

SKU:Belden 8641 060
● En stock
Description
Belden 8641 060 is a 1-pair, 24 AWG stranded control/audio cable with a PVC outer jacket and CM rating for indoor general-purpose runs. It uses 24AWG (7x32) TC - Tinned Copper conductors with PE - Polyethylene insulation, plus an overall Beldfoil® shield and a 24 AWG (7x32) TC drainwire. Electrical characteristics include 80 Ohm impedance, 22 pF/ft (72 pF/m) capacitance Cond-to-Cond, and a UL voltage rating of 300 V (CM), 300 V (UL AWM 2092).
Belden 8641 060 Key Features
- 1-pair construction with 24 AWG stranded conductors (7x32) for control/audio signal wiring.
- TC - Tinned Copper conductors with PE - Polyethylene insulation.
- Overall Beldfoil® shield (tape, bi-laminate (Alum+Poly), 100% coverage) with a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket with CM rating for indoor general-purpose runs.
- UL voltage rating: 300 V (CM), 300 V (UL AWM 2092).
Belden 8641 060 Technical Specs
Physical Construction & Dimensions
| Color code | Black & Clear |
|---|---|
| Nom. thickness (insulation) | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.056 in (1.4 mm) |
| Nom. thickness (jacket) | 0.025 in (0.64 mm) |
| Nom. diameter | 0.168 in (4.27 mm) |
| Overall cable diameter (nominal) | 0.168 in (4.27 mm) |
| Bulk cable weight | 12 lbs/1000ft |
| Plenum number | 88641, 82641 |
Electrical Characteristics
| Nom. conductor DCR | 28.8 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-other (conds + Shield) | 42 pF/ft (140 pF/m) |
| Nom. inductance | 0.22 μH/ft (0.72 μH/m) |
| Max. current | 3.8 Amps per Conductor at 30ºC |
| Nom outer Shield DCR | 17.42 Ohm/1000ft (57.15 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 1.7 in (43 mm) |
| Bend radius (installation min.) | 1.7 in (43 mm) |
| Max. pull tension | 16.5 lbs (7.48 kg) |
| Environmental suitability | Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2092 |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Applications
- Use for low voltage analog signals (4-20ma, 0-10v, ...) where consistent signal transmission is needed.
- Support low voltage digital control (24v, …) in control and automation-style wiring.
- Choose for line level audio connections in installed audio signal paths.
- Use in computer communication links where shielded signal cable is specified.
- Fit panel wiring layouts for organized internal wiring and interconnects.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Color Code | Black & Clear |
| Nom. thickness (insulation) | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.056 in (1.4 mm) |
| Nom. thickness (jacket) | 0.025 in (0.64 mm) |
| Nom. diameter | 0.168 in (4.27 mm) |
| Overall cable diameter (nominal) | 0.168 in (4.27 mm) |
| Bulk cable weight | 12 lbs/1000ft |
| Plenum number | 88641, 82641 |
| Nom. conductor DCR | 28.8 Ohm/1000ft |
| Nom. capacitance cond-to-other (conds + Shield) | 42 pF/ft (140 pF/m) |
| Nom. inductance | 0.22 µH/ft (0.72 µH/m) |
| Max. current | 3.8 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 17.42 Ohm/1000ft (57.15 Ohm/km) |
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Bend radius (stationary min.) | 1.7 in (43 mm) |
| Bend radius (installation min.) | 1.7 in (43 mm) |
| Max Pull Tension | 16.5 lbs (7.48 kg) |
| Environmental suitability | Indoor |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2092 |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.