Belden 8761 060 is a 1 pair, 22 AWG multi pair cable with a PVC outer jacket and CM rating for indoor installations. It features 22 AWG (7x30) TC - Tinned Copper conductors with PE - Polyethylene insulation and an overall Beldfoil® shield. The design includes 100% tape shield coverage and a 22 AWG (7x30) TC drainwire to support shielding and grounding performance. Electrical characteristics include 18.2 Ohm/1000ft DCR, 24 pF/ft (79 pF/m) capacitance cond-to-cond, and a UL Voltage Rating of 300 V (CM), 300 V (UL AWM 2092)).
Belden 8761 060 Key Features
- 1 pair construction with 22 AWG conductors for control, instrumentation, and communication wiring.
- 22 AWG (7x30) TC - Tinned Copper conductors with PE - Polyethylene insulation.
- Overall Beldfoil® tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage.
- Includes a 22 AWG (7x30) TC drainwire for grounding and shielding continuity.
- PVC - Polyvinyl Chloride outer jacket with CM rating for indoor installations.
Belden 8761 060 Technical Specs
Construction & Materials
| Number of pairs | 1 |
| Construction | 2 Conductor 22AWG (7x30) Tinned Copper |
| Conductor size | 22 AWG |
| Stranding | 7x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PE - Polyethylene |
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Color code | Black, Clear |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
Physical Dimensions & Weight
| Jacket thickness (nom.) | 0.025 in (0.64 mm) |
| Overall cable diameter (nominal) | 0.175 in (4.45 mm) |
| Bulk cable weight | 16 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. Conductor DCR | 18.2 Ohm/1000ft |
| Capacitance (cond-to-cond, nom.) | 24 pF/ft (79 pF/m) |
| Capacitance (cond-to-other, nom.) | 47 pF/ft (150 pF/m) |
| Characteristic impedence (nom.) | 64 Ohm |
| Inductance (nom.) | 0.2 μH/ft (0.66 μH/m) |
| Max. current | 6 Amps per Conductor at 30ºC |
| UL Voltage Rating | 300 V (CM), 300 V (UL AWM 2092)) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
| Operating temperature | -20°C to +60°C |
| Stationary min. bend radius | 1.8 in (46 mm) |
| Installation min. bend radius | 1.8 in (46 mm) |
| Max. pull tension | 27.3 lbs (12.4 kg) |
| Environmental suitability | Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2092 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Plenum number | 88761, 87761, 82761 |
Applications
- Use it for low voltage analog signals (4-20ma, 0-10v, ...) in control and instrumentation wiring.
- Support low voltage digital control (24v, …) where consistent signal transmission is needed.
- Run line level audio connections in indoor wiring and panel environments.
- Choose it for computer communication wiring where shielded signal cabling is required.
- Install it for panel wiring in indoor environments.
Belden™ and all associated trademarks are the property of their respective owners.