Belden 9201 010 is an RG-58/U coaxial cable for 50 Ohm wireless transmission in point-to-point and point-to-multipoint antenna communication systems. It features a 1 x 20 AWG solid bare copper conductor with PE - Polyethylene insulation and an 80% bare copper braid shield. A PVC - Polyvinyl Chloride jacket and 0.193 in (4.90 mm) nominal overall diameter support flexible indoor installations.
Belden 9201 010 Key Features
- RG-58/U coaxial construction for wireless transmission in point-to-point and point-to-multipoint antenna communication systems.
- 1 x 20 AWG solid bare copper conductor with PE - Polyethylene insulation.
- 80% coverage bare copper braid shield.
- PVC - Polyvinyl Chloride jacket with 0.193 in (4.90 mm) nominal overall diameter for flexible indoor installations.
Belden 9201 010 Technical Specs
Construction & Materials
| Coax type | RG-58/U |
|---|---|
| Conductor | 1 x 20 AWG, solid, BC - Bare Copper |
| Nom. conductor diameter | 0.033 in |
| Insulation material | PE - Polyethylene |
| Nom. insulation diameter | 0.116 in (2.95 mm) |
| Insulation color code | White |
| Outer shield | Braid, Bare Copper (BC), 80% coverage |
| Jacket material | PVC - Polyvinyl Chloride |
| Overall cable diameter (nominal) | 0.193 in (4.90 mm) |
Electrical Characteristics
| Nom. characteristic impedance | 52 Ohm |
|---|---|
| Voltage rating | 1900 V RMS |
| Nom. capacitance cond-to-shield | 28.5 pF/ft (93.5 pF/m) |
| Nom. velocity of prop. | 66% |
| Nom. conductor DCR | 10.3 Ohm/1000ft (33.8 Ohm/km) |
| Nom. outer shield DCR | 7.1 Ohm/1000ft (23 Ohm/km) |
Attenuation (Nominal)
| Attenuation (nominal) 1 MHz | 0.3 dB/100ft |
|---|---|
| Attenuation (nominal) 10 MHz | 1.1 dB/100ft |
| Attenuation (nominal) 50 MHz | 2.5 dB/100ft |
| Attenuation (nominal) 100 MHz | 3.8 dB/100ft |
| Attenuation (nominal) 200 MHz | 5.6 dB/100ft |
| Attenuation (nominal) 400 MHz | 8.4 dB/100ft |
| Attenuation (nominal) 700 MHz | 11.7 dB/100ft |
| Attenuation (nominal) 900 MHz | 13.7 dB/100ft |
| Attenuation (nominal) 1000 MHz | 14.5 dB/100ft |
Environmental & Mechanical Ratings
| Operating temperature | -30°C to +80°C |
|---|---|
| Bend radius (stationary min.) | 1.93 in (49.0 mm) |
| Bend radius (installation min.) | 1.93 in (49.0 mm) |
| Max. pull tension | 72 lbs (33 kg) |
| Bulk cable weight | 23 lbs/1000ft (34 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| Flammability / reaction to fire | IEC 60332-1-2 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Designed for point-to-point and point-to-multipoint wireless antenna communication.
- Commonly used in wireless microphone setups where coaxial signal routing is required.
- Supports two-way radio installations that use coaxial connections between equipment and antennas.
- Used in Amateur (Ham) Radio systems for antenna feed and related RF connections.
- Applied in Low Power FM systems where coaxial cable is needed for RF signal transmission.
- Suitable for GPS installations that require coaxial connectivity.
- Implemented in RFID (Radio Frequency Identification) systems where coaxial connections are part of the RF signal path.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Coax Type | RG-58/U |
| Conductor | 1 x 20 AWG, solid, BC - Bare Copper |
| Nom. conductor diameter | 0.033 in |
| Insulation Material | PE - Polyethylene |
| Nom. insulation diameter | 0.116 in (2.95 mm) |
| Insulation color code | White |
| Outer shield | Braid, Bare Copper (BC), 80% coverage |
| Jacket Material | PVC - Polyvinyl Chloride |
| Overall cable diameter (nominal) | 0.193 in (4.90 mm) |
| Nom. characteristic impedance | 52 Ohm |
| Voltage Rating | 1900 V RMS |
| Nom. capacitance (Cond-to-Shield) | 28.5 pF/ft (93.5 pF/m) |
| Nom. velocity of prop. | 66% |
| Nom. conductor DCR | 10.3 Ohm/1000ft (33.8 Ohm/km) |
| Nom. outer shield DCR | 7.1 Ohm/1000ft (23 Ohm/km) |
| Attenuation (nominal) 1 MHz | 0.3 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.1 dB/100ft |
| Attenuation (nominal) 50 MHz | 2.5 dB/100ft |
| Attenuation (nominal) 100 MHz | 3.8 dB/100ft |
| Attenuation (nominal) 200 MHz | 5.6 dB/100ft |
| Attenuation (nominal) 400 MHz | 8.4 dB/100ft |
| Attenuation (nominal) 700 MHz | 11.7 dB/100ft |
| Attenuation (nominal) 900 MHz | 13.7 dB/100ft |
| Attenuation (nominal) 1000 MHz | 14.5 dB/100ft |
| Operating temperature | -30°C to +80°C |
| Bend radius (stationary min.) | 1.93 in (49.0 mm) |
| Bend radius (installation min.) | 1.93 in (49.0 mm) |
| Max Pull Tension | 72 lbs (33 kg) |
| Bulk cable weight | 23 lbs/1000ft (34 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| Flammability / reaction to fire | IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.