Belden 9464 060U, Multi Pair Cable 1 Pair 20 AWG PE PVC Jacket

SKU:Belden 9464 060U
● En stock
Description
Belden 9464 060U is a 1 pair, 20 AWG multi-conductor cable for low-voltage signal and control applications. It features 2 stranded 20 AWG (7x28) TC - Tinned Copper conductors with PE - Polyethylene insulation, plus an overall shield and drain for noise rejection. A PVC - Polyvinyl Chloride outer jacket and NEC / UL compliance: Article 800, CM support general-purpose installations such as panel wiring, computer communication, and line level audio.
Belden 9464 060U Key Features
- 1 pair construction with 2 stranded 20 AWG (7x28) TC - Tinned Copper conductors for low-voltage signal and control wiring.
- Overall shield & drain using tape with Bi-Laminate (Alum+Poly) and 100% coverage to help reduce noise in signal paths.
- Drainwire type: 20 AWG (7x28) TC for a consistent shield termination point.
- PE - Polyethylene insulation and a PVC - Polyvinyl Chloride outer jacket for general-purpose cable construction.
- NEC / UL compliance: Article 800, CM and UL voltage rating: 300 V for specified installation and electrical requirements.
Belden 9464 060U Technical Specs
Construction & Materials
| Number of conductors | 2 |
|---|---|
| Conductor size | 20 AWG (American Wire Gauge) |
| Conductor stranding | 7x28 |
| Conductor material | TC - Tinned Copper |
| Conductor type | Stranded Conductor |
| Insulation material | PE - Polyethylene |
| Color code | Black, White |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Shield | Yes |
| Shield construction | Overall Shield & drain |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
Dimensions & Weight
| Nom. thickness (Insulation) | 0.016 in (0.41 mm) |
|---|---|
| Nom. insulation diameter | 0.70 in (18 mm) |
| Nom. thickness (Jacket) | 0.035 in (0.89 mm) |
| Nom. diameter | 0.214 in (5.44 mm) |
| Bulk cable weight | 30 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 11.1 Ohm/1000ft |
|---|---|
| Nom outer shield DCR | 7.51 Ohm/1000ft (24.6 Ohm/km) |
| Nom. capacitance Cond-to-Cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 49 pF/ft (160 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance | 0.18 μH/ft (0.59 μH/m) |
| Max. current | 3.9 Amps per Conductor at 20ºC |
Environmental & Mechanical Ratings
| Environmental suitability | Indoor, Outdoor |
|---|---|
| UL temperature | 60°C |
| Operating | -20°C To +60°C |
| Stationary min. bend radius | 2.14 in (54.4 mm) |
| Installation min. bend radius | 2.14 in (54.4 mm) |
| Max. pull tension | 31.2 lbs (14.2 kg) |
Compliance & Certifications
| CEC / C(UL) compliance | CM |
|---|---|
| AWM compliance | AWM 2092 |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9464 060U Applications
- Use it for automatic stripping equipments where consistent handling and termination are needed.
- Support low voltage analog signals (4-20ma, 0-10v, ...) in signal and control circuits.
- Handle low voltage digital control (24v, …) for common control and automation signaling.
- Choose it for line level audio connections where signal integrity is important.
- Install it in computer communication wiring where shielded signal cabling is required.
- Apply it to panel wiring for general-purpose control and signal distribution.
Belden™ and all associated trademarks are the property of their respective owners.
Spécifications
| Attribute | Value |
|---|---|
| Number of Conductors | 2 |
| Conductor size | 20 AWG (American Wire Gauge) |
| Conductor stranding | 7x28 |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded Conductor |
| Insulation Material | PE - Polyethylene |
| Color Code | Black, White |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Shield | Yes |
| Shield construction | Overall Shield & drain |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Coverage | 100% |
| Nom. thickness (insulation) | 0.016 in (0.41 mm) |
| Nom. insulation diameter | 0.70 in (18 mm) |
| Nom. thickness (jacket) | 0.035 in (0.89 mm) |
| Nom. diameter | 0.214 in (5.44 mm) |
| Bulk cable weight | 30 lbs/1000ft |
| Nom. conductor DCR | 11.1 Ohm/1000ft |
| Nom. outer shield DCR | 7.51 Ohm/1000ft (24.6 Ohm/km) |
| Nom. capacitance cond-to-cond | 27 pF/ft (89 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 49 pF/ft (160 pF/m) |
| Nom. characteristic impedence | 56 Ohm |
| Nom. inductance | 0.18 µH/ft (0.59 µH/m) |
| Max. current | 3.9 Amps per Conductor at 20ºC |
| Environmental suitability | Indoor, Outdoor |
| UL temperature | 60°C |
| Operating | -20°C To +60°C |
| Stationary min. bend radius | 2.14 in (54.4 mm) |
| Installation min. bend radius | 2.14 in (54.4 mm) |
| Max Pull Tension | 31.2 lbs (14.2 kg) |
| CEC / C(UL) compliance | CM |
| AWM compliance | AWM 2092 |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Les images sont fournies à titre indicatif uniquement. Les spécifications peuvent changer sans préavis — vérifiez l'adéquation à votre application avant l'achat. La documentation du fabricant fait foi.
Besoin d'une coupe sur mesure, d'un prix de gros ou d'une fiche technique ?
Notre équipe établit des devis pour les longueurs personnalisées et les commandes en gros, généralement le jour même.