Belden 9913F7 B59 Coax Transmission sans fil 50 Ohm 10 AWG

Description
Belden 9913F7 B59 est un câble coaxial de transmission sans fil de 50 Ohm. Il s’agit d’un câble RG-8 avec un conducteur en cuivre nu 10 AWG (7x18) et une gaine en PVC noir mat. Le câble est doté d’une isolation en PE, d’un feuillard + une tresse en cuivre étamé à 90 % Blindage, et d’une construction flexible.
Applications
- Utilisation dans des installations coaxiales de transmission sans fil nécessitant un câble coaxial de 50 Ohm.
Spécifications
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| RG type | 8 |
| Conductor nominal diameter | 0.108 in |
| Nominal insulation diameter | 0.284 in (7.21 mm) |
| Overall cable diameter (nominal) | 0.405 in (10.3 mm) |
| Bulk cable weight | 104 lbs/1000ft |
| Nominal conductor DCR | 1.1 Ohm/1000ft |
| Nominal outer shield DCR | 1.8 Ohm/1000ft (5.9 Ohm/km) |
| Nominal Capacitance (Cond-to-Shield) | 22.5 pF/ft (73.8 pF/m) |
| Nominal velocity of prop. | 85% |
| VSWR frequency range | 5-2250 MHz |
| Max. VSWR | 1.43:1 |
| Attenuation (Nominal) | 10 MHz: 0.6 dB/100ft; 50 MHz: 1.1 dB/100ft; 100 MHz: 1.5 dB/100ft; 200 MHz: 2.0 dB/100ft; 400 MHz: 3.0 dB/100ft; 700 MHz: 4.0 dB/100ft; 900 MHz: 4.7 dB/100ft; 1000 MHz: 5.0 dB/100ft; 2000 MHz: 7.5 dB/100ft; 2250 MHz: 8.0 dB/100ft; 3000 MHz: 9.8 dB/100ft; 4000 MHz: 12.1 dB/100ft |
| Power rating (max.) | 5 MHz: 3,217 W; 10 MHz: 2,681 W; 50 MHz: 1,463 W; 100 MHz: 1,073 W; 200 MHz: 805 W; 400 MHz: 575 W; 700 MHz: 424 W; 1,000 MHz: 350 W; 1,500 MHz: 278 W; 2,000 MHz: 237 W; 3,000 MHz: 188 W; 4,000 MHz: 157 W |
| Minimum bend radius (installation) | 4 in (100 mm) |
| Max Pull Tension | 210 lbs (95 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
| Sustainability | CA Prop 65 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 9913F7 B59100, 9913F7 B59250, 9913F7 B59500, 9913F7 B591000, UPC 612825261735 |
| Priced Per | FT |