Contatti1-800-975-3686
Ramcorp Wire & Cable

Belden 1075A 2 coppie 20 + 1/C 22 SPOS PLTCAWG -ER Nero PVC guaina

Belden 1075A 010

SKU:Belden 1075A

$283.20

Disponibile

Descrizione

Specifiche

Belden 1075A 2 coppie 20 + 1/C 22 SPOS PLTCAWG -ER Nero PVC guaina specifications
AttributeValue
Pairs2
Pair Conductor Size20 AWG
Pair Stranding7x28
Pair Conductor MaterialBC - Bare Copper
Comm wire1
Comm Wire size22 AWG
Comm Wire stranding7x30
Comm Wire materialBC - Bare Copper
Conductor TypeStranded Conductor
Pair insulation materialPVC - Polyvinyl Chloride
Pair nominal insulation thickness0.018 in (0.46 mm)
Pair nominal Insulation Diameter0.071 in (1.8 mm)
Pair color codeICEA Chart E1
Comm wire insulation materialPVC - Polyvinyl Chloride
Comm wire nominal insulation thickness0.019 in (0.48 mm)
Comm wire nominal insulation diameter0.066 in (1.7 mm)
Comm Wire colorOrange
Inner shield (pair(s))Tape, Bi-Laminate (Alum+Poly), 100% coverage, drainwire 22 AWG (7x30) TC (each pair)
Outer shieldTape, Bi-Laminate (Alum+Poly), 100% coverage, drainwire 20 AWG (7x28) TC
RipcordYes
ArmorNo
Outer jacket nominal thickness0.042 in (1.1 mm)
Overall cable diameter (nominal)0.365 in (9.27 mm)
Bulk cable weight61 lbs/1000ft
Pair nominal Conductor DCR9.5 Ohm/1000ft
Pair nominal inner Shield DCR12.86 Ohm/1000ft (42.19 Ohm/km)
Nom. outer shield DCR6.5 Ohm/1000ft (21 Ohm/km)
Max. Current (pair(s))6.4 Amps per Conductor @ 30°C
Comm Wire nominal Conductor DCR17.2 Ohm/1000ft (56.4 Ohm/km)
Max. current (comm wire)9.6 Amps per Conductor @ 30°C
Bend radius (stationary min.)4.38 in (111 mm)
Bend radius (installation min.)4.38 in (111 mm)
Max Pull Tension81 lbs (37 kg)
UL instrumentationUL Instrumentation
NEC / UL complianceArticle 725, Article 727, Article 800, CMG, ITC, PLTC
AWM complianceAWM 2464
CEC / C(UL) complianceCMG
Flammability / reaction to fireUL 1685 FT4 Loading, FT4, T-29-520, IEEE 1202 FT4
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Instrumentation Cable
Priced PerFT

Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.

Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?

Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.