Belden 1506A N3U SDI Coassiale RG-59 20 AWG BC FEP CMP

Descrizione
Belden 1506A N3U è un cavo coassiale SDI da 75 Ohm con costruzione RG-59 e conduttore in rame nudo da 20 AWG. È dotato di isolamento in schiuma FEP, schermatura in lamina + treccia in rame stagnato al 95% Schermatura e guaina in PVC Mil Green Guaina. Questo cavo ha rating CMP.
Applicazioni
- Da utilizzare per connettività coassiale SDI quando è richiesto un cavo da 75 Ohm.
- Da scegliere per installazioni che richiedono la costruzione RG-59.
- Da selezionare per tratte in cui è specificato un cavo con rating CMP.
Specifiche
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Overall cable diameter (nominal) | 0.196 in (4.98 mm) |
| Nom. Diameter (conductor) | 0.032 in |
| Nom. insulation diameter | 0.133 in (3.38 mm) |
| Insulation color code | White |
| Bulk cable weight | 29 lbs/1000ft |
| Non-Plenum number | 1505A |
| Nom. velocity of prop. | 84% |
| Nom. capacitance (Cond-to-Shield) | 16.1 pF/ft (52.8 pF/m) |
| Nom. conductor DCR | 10 Ohm/1000ft |
| Nom. outer shield DCR | 3.2 Ohm/1000ft (10 Ohm/km) |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (nominal) 1 MHz | 0.29 dB/100ft |
| Attenuation (Nominal) 3.58 MHz | 0.62 dB/100ft |
| Attenuation (Nominal) 5 MHz | 0.7 dB/100ft |
| Attenuation (Nominal) 7 MHz | 0.82 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.05 dB/100ft |
| Attenuation (Nominal) 67.5 MHz | 2.2 dB/100ft |
| Attenuation (Nominal) 71.5 MHz | 2.25 dB/100ft |
| Attenuation (nominal) 100 MHz | 2.7 dB/100ft |
| Attenuation (Nominal) 135 MHz | 3.2 dB/100ft |
| Attenuation (Nominal) 143 MHz | 3.25 dB/100ft |
| Attenuation (Nominal) 180 MHz | 3.65 dB/100ft |
| Attenuation (Nominal) 270 MHz | 4.55 dB/100ft |
| Attenuation (Nominal) 360 MHz | 5.25 dB/100ft |
| Attenuation (Nominal) 540 MHz | 6.4 dB/100ft |
| Attenuation (Nominal) 720 MHz | 7.3 dB/100ft |
| Attenuation (Nominal) 750 MHz | 7.5 dB/100ft |
| Attenuation (nominal) 1000 MHz | 9.4 dB/100ft |
| Attenuation (Nominal) 1500 MHz | 11.3 dB/100ft |
| Attenuation (Nominal) 2250 MHz | 17.50 dB/100ft |
| Attenuation (Nominal) @ 3000 MHz | 21.90 dB/100ft |
| Attenuation (Nominal) 4500 MHz | 21.8 dB/100ft |
| Attenuation (Nominal) 6000 MHz | 25.9 dB/100ft |
| UL Voltage Rating | 300 V (CMP) |
| UL temperature | 75°C |
| Operating | 0°C to +75°C |
| Installation min. bend radius | 2 in (51 mm) |
| Max Pull Tension | 52 lbs (24 kg) |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable RG59 |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.