Contatti1-800-975-3686
Ramcorp Wire & Cable

Belden 1694A 007, RG6 18 Solid BC Duofoil+95% PVC Jacket CMR ROHS, Violet Jacket

Belden 1694A 007, RG6 18 Solid BC Duofoil+95% PVC Jacket CMR ROHS, Violet Jacket

SKU:Belden 1694A 007

$1,370.00

Disponibile

Descrizione

Specifiche

Belden 1694A 007, RG6 18 Solid BC Duofoil+95% PVC Jacket CMR ROHS, Violet Jacket specifications
AttributeValue
Coax constructionCoaxial
Coax TypeRG-6
RG type6
Overall cable diameter (nominal)0.274 in (6.96 mm)
Conductor nom. diameter0.040 in
Nom. insulation diameter0.180 in (4.57 mm)
Shield TypeBoth, braid over foil
FloodedNo not flooded over braid
Jacket nom. diameter0.274 in (6.96 mm)
OutdoorNo not outdoor grade material
Bulk cable weight41 lbs/1000ft (61 kg/km)
Plenum number1695A
Nom. conductor DCR6.4 Ohm/1000ft (21 Ohm/km)
Nom. outer shield DCR3.8 Ohm/1000ft (12 Ohm/km)
Nom. capacitance (Cond-to-Shield)16.2 pF/ft (53.1 pF/m)
Nom. velocity of prop.82%
Return loss (5 - 1600 MHz)23 dB
Return loss (1600 - 4500 MHz)21 dB
Return loss (4500 - 6000 MHz)15 dB
Attenuation (nominal) 1 MHz0.24 dB/100ft
Attenuation (Nominal) 3.58 MHz0.44 dB/100ft
Attenuation (Nominal) 5 MHz0.52 dB/100ft
Attenuation (Nominal) 6 MHz0.57 dB/100ft
Attenuation (Nominal) 7 MHz0.61 dB/100ft
Attenuation (nominal) 10 MHz0.71 dB/100ft
Attenuation (Nominal) 12 MHz0.78 dB/100ft
Attenuation (Nominal) 25 MHz1.08 dB/100ft
Attenuation (Nominal) 67.5 MHz1.65 dB/100ft
Attenuation (Nominal) 71.5 MHz1.69 dB/100ft
Attenuation (Nominal) 88.5 MHz1.86 dB/100ft
Attenuation (nominal) 100 MHz1.95 dB/100ft
Attenuation (Nominal) 135 MHz2.24 dB/100ft
Attenuation (Nominal) 143 MHz2.3 dB/100ft
Attenuation (Nominal) 180 MHz2.57 dB/100ft
Attenuation (Nominal) 270 MHz3.17 dB/100ft
Attenuation (Nominal) 360 MHz3.69 dB/100ft
Attenuation (Nominal) 540 MHz4.5 dB/100ft
Attenuation (Nominal) 720 MHz5.3 dB/100ft
Attenuation (Nominal) 750 MHz5.4 dB/100ft
Attenuation (nominal) 1000 MHz6.3 dB/100ft
Attenuation (Nominal) 1500 MHz7.8 dB/100ft
Attenuation (Nominal) 2000 MHz9.2 dB/100ft
Attenuation (Nominal) 2250 MHz9.8 dB/100ft
Attenuation (Nominal) @ 3000 MHz11.5 dB/100ft
Attenuation (Nominal) 4500 MHz14.5 dB/100ft
Attenuation (Nominal) 6000 MHz17.7 dB/100ft
UL temperature60°C
Operating temperature-30°C to +75°C
Installation min. bend radius2.75 in (69.9 mm)
Max Pull Tension69 lbs (31 kg)
Fire ratingRiser
Flammability / reaction to fireUL1666 Vertical Shaft
Environmental suitabilityIndoor/Outdoor, Indoor, UV Resistance, Aerial - Black only, When supported by messenger Wire
NEC / UL complianceCMR
CEC / C(UL) complianceCMG
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Priced PerFT

Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.

Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?

Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.