Belden 27917A, Power Limited Tray Cable 2C 16 AWG 600V PVC Jacket

SKU:Belden 27917A
● Disponibile
Descrizione
Belden 27917A is a power limited tray cable for power and control applications up to 600V. It is built with 2 stranded 16 AWG (7x24) BC - Bare Copper conductors, PVC/Nylon - Polyvinyl Chloride + Nylon insulation, and a black PVC - Polyvinyl Chloride outer jacket. This unshielded TC cable is rated 90°C Dry, 90°C Wet and supports Wet/Dry: -30°C to 90°C operation. It also includes a ripcord for easier jacket removal and is listed for Indoor, Outdoor, Sunlight Resistance, and Burial environments.
Belden 27917A Key Features
- Power limited tray cable designed for power and control applications up to 600V.
- 2 stranded 16 AWG (7x24) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation.
- Black PVC - Polyvinyl Chloride outer jacket with a ripcord for easier jacket removal.
- Unshielded design (Shield: No Shield) with UL temperature ratings of 90°C Dry, 90°C Wet.
- Suitable for Indoor, Outdoor, Sunlight Resistance, and Burial environments.
Belden 27917A Technical Specs
Construction & Dimensions
| UL type | TC (1277) PVC-Nylon/PVC |
|---|---|
| Product type | VNTC Control |
| Insulation nominal thickness | 0.020 in (0.51 mm) |
| Insulation nominal diameter | 0.099 in (2.5 mm) |
| Color code | Black, Red |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.197 x 0.298 in |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
Electrical Characteristics
| UL voltage rating | 600 V (TC), 150 V (NPLF) |
|---|---|
| Nominal conductor DCR | 4.2 Ohm/1000ft |
| Max. current | 18 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| Operating | Wet/Dry: -30°C to 90°C |
|---|---|
| Bend radius (stationary min.) | 1.192 in (30.28 mm) |
| Bend radius (installation min.) | 1.49 in (37.8 mm) |
| Max. pull tension | 71 lbs (32 kg) |
| Bulk cable weight | 41 lbs/1000ft |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
Compliance & Certifications
| NEC / UL compliance | Article 336, NPLF, TC, TFFN |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2) |
| Factory marking | 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR |
Belden 27917A Applications
- Handles power and control applications up to 600V.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| UL type | TC (1277) PVC-Nylon/PVC |
| Product type | VNTC Control |
| Insulation nominal thickness | 0.020 in (0.51 mm) |
| Insulation nominal diameter | 0.099 in (2.5 mm) |
| Color Code | Black, Red |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Overall cable diameter (nominal) | 0.197 x 0.298 in |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| UL Voltage Rating | 600 V (TC), 150 V (NPLF) |
| Nominal conductor DCR | 4.2 Ohm/1000ft |
| Max. current | 18 Amps per Conductor at 30ºC |
| Operating | Wet/Dry: -30°C to 90°C |
| Bend radius (stationary min.) | 1.192 in (30.28 mm) |
| Bend radius (installation min.) | 1.49 in (37.8 mm) |
| Max Pull Tension | 71 lbs (32 kg) |
| Bulk cable weight | 41 lbs/1000ft |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, NPLF, TC, TFFN |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2) |
| Factory Marking | 600V TC 150V NPLF 90C Wet/Dry SUN RES DIR BUR |
| Priced Per | FT |