Belden 28081A, Power Limited Tray Cable 3C 14 AWG 600V PVC

SKU:Belden 28081A
● Disponibile
Descrizione
Belden 28081A is a power limited tray cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations. It is built with 3 stranded 14 AWG (7x22) BC - Bare Copper conductors and PVC/Nylon - Polyvinyl Chloride + Nylon insulation in an unshielded design. The cable features a black PVC - Polyvinyl Chloride outer jacket with ripcord and is rated UL Type TC (1277) and TC-ER. It is suitable for indoor/outdoor use with SUN RES and DIR BUR performance.
Belden 28081A Key Features
- Power limited tray cable for power and control applications up to 600V, including Class 1 Division 2 hazardous locations.
- 3 stranded 14 AWG (7x22) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation.
- Unshielded construction supports straightforward terminations.
- Black PVC - Polyvinyl Chloride outer jacket with ripcord supports easier installation.
- UL Type TC (1277) and TC-ER ratings.
- Suitable for indoor/outdoor use with SUN RES and DIR BUR performance.
Belden 28081A Technical Specs
Construction & Materials
| Product type | VNTC Control |
|---|---|
| Number of conductors | 3 |
| Conductor size | 14 AWG |
| Stranding | 7x22 |
| Conductor material | BC - Bare Copper |
| Insulation material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color code | Black, Red, Blue |
| Shield | No Shield |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
Dimensions & Weight
| Insulation nominal thickness | 0.024 in (0.61 mm) |
|---|---|
| Insulation nominal diameter | 0.116 in (2.95 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.335 in (8.51 mm) |
| Overall cable diameter (nominal) | 0.346 in (8.79 mm) |
| Bulk cable weight | 74 lbs/1000ft |
Electrical Characteristics
| UL voltage rating | 600 V (TC-ER), 150 V (NPLF) |
|---|---|
| Nom. conductor DCR | 2.67 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| UL temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating (wet/dry) | -30°C to 90°C |
| Bend radius (stationary min.) | 1.384 in (35.15 mm) |
| Bend radius (installation min.) | 1.73 in (43.9 mm) |
| Max. pull tension | 164 lbs (74.4 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
Compliance & Certifications
| NEC / UL compliance | Article 336, NPLF, TC-ER, THWN-2 |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 28081A Applications
- Use it for power and control applications up to 600V.
- Specify it for Class 1 Division 2 hazardous locations.
- Select the recommended cable gland: Belden BTC075A0551RA.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Product type | VNTC Control |
| Number of Conductors | 3 |
| Conductor size | 14 AWG |
| Stranding | 7x22 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC/Nylon - Polyvinyl Chloride + Nylon |
| Color Code | Black, Red, Blue |
| Shield | No Shield |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Ripcord | Yes |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Insulation nominal thickness | 0.024 in (0.61 mm) |
| Insulation nominal diameter | 0.116 in (2.95 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.335 in (8.51 mm) |
| Overall cable diameter (nominal) | 0.346 in (8.79 mm) |
| Bulk cable weight | 74 lbs/1000ft |
| UL Voltage Rating | 600 V (TC-ER), 150 V (NPLF) |
| Nom. conductor DCR | 2.67 Ohm/1000ft |
| Max. current | 24 Amps per Conductor at 30ºC |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating (wet/dry) | -30°C to 90°C |
| Bend radius (stationary min.) | 1.384 in (35.15 mm) |
| Bend radius (installation min.) | 1.73 in (43.9 mm) |
| Max Pull Tension | 164 lbs (74.4 kg) |
| Flammability / reaction to fire | UL1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, NPLF, TC-ER, THWN-2 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?