Belden 29507 010, Cavo VFD, 3-2 AWG TC + 1G TC, XLPE, schermato, rivestimento in PVC nero

SKU:Belden 29507 010
$5,146.80
● Disponibile
Descrizione
Belden 29507 010, Cavo VFD, 3-2 AWG TC + 1G TC, isolamento XLPE, schermato, rivestimento in PVC nero
Cavo VFD flessibile Belden 300% terra / Cavo di alimentazione motore flessibile 1000V UL
3-2 AWG in rame stagnato a trefoli (7x19x23) + conduttori di terra TC 1-2 AWG
Isolamento XLPE, codice colore M4 + pavimento isolato in PVC
Tuta Beldfoil® + 85% scudo trecciato TC + filo di drenaggio TC
Rivestimento in PVC resistente al sole e all'olio
600/1000 V TC-ER, 90ºC umido/secco
Specifiche
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 2 AWG |
| Conductor stranding | 7x19x23 |
| Conductor Material | TC - Tinned Copper |
| Insulated ground | 1 x 2 AWG, 7x19x23, TC - Tinned Copper (insulated ground wire) |
| Segmented ground wire | 4 x 8 AWG, 7x19x29, TC - Tinned Copper (4 totaling 2 AWG) |
| Conductor insulation material | XLPE - Cross-Linked Polyethylene (Thermoset) |
| Conductor insulation nominal thickness | 0.062 in (1.6 mm) |
| Conductor nominal insulation diameter | 0.454 in (11.5 mm) |
| Ground wire insulation material | PVC - Polyvinyl Chloride |
| Ground wire insulation nominal thickness | 0.062 in (1.6 mm) |
| Ground wire nominal insulation diameter | 0.454 in (11.5 mm) |
| Ground wire color | Green/Yellow Stripe |
| Shielded | Yes |
| Shield Type | Braid |
| Drainwire type | 8 AWG (7x19x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Jacket Color | Black |
| Outer jacket nominal thickness | 0.095 in (2.4 mm) |
| Overall cable diameter (nominal) | 1.324 in (33.63 mm) |
| Armor | No |
| Composite | No |
| TC SUN RES DIR BUR | |
| Nom. conductor DCR | 0.152 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 66 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 46 Ohm |
| Nom. inductance cond-grnd | 0.098 µH/ft |
| Nom. velocity of prop. | 55% |
| Max. current | 130 Amps per Conductor at 30ºC |
| Insulated ground DCR | 0.147 Ohm/1000ft (0.482 Ohm/km) |
| Nom. outer shield DCR | 0.43 Ohm/1000ft (1.4 Ohm/km) |
| UL Voltage Rating | 1000 V (TC-ER, WTTC, UL44, UL Flexible Motor Supply Cable), 600 V (C(UL) CIC TC) |
| Voltage Rating | 1000 V (AWM I/II A/B) |
| Voltage range | 1KV |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating temperature | -40°C To +90°C |
| Bend radius (stationary min.) | 15.9 in (404 mm) |
| Bend radius (installation min.) | 15.9 in (404 mm) |
| Max Pull Tension | 3987 lbs (1808 kg) |
| Bulk cable weight | 1546 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, TC-ER, WTTC, UL Flexible Motor Supply Cable |
| AWM compliance | AWM I/II A/B |
| CEC / C(UL) compliance | CIC, TC |
| ICEA compliance | S-95-658 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-07-KA070003-MSHA |
| Sustainability | CA Prop 65 |
| Other Part Numbers | 29507 010, 29507 010100, 29507 010250, 29507 010500, 29507 0101000 |