Belden 29529 010, Cavo VFD, 3C-1/0 AWG TC + 3G-4 AWG BC, XLPE, schermato, guaina nera

Belden 29529

SKU:Belden 29529 010

$1,962.50

Disponibile

Descrizione

Specifiche

Belden 29529 010, Cavo VFD, 3C-1/0 AWG TC + 3G-4 AWG BC, XLPE, schermato, guaina nera specifications
AttributeValue
Product typeVFD
Number of Conductors3
Conductor size1/0 AWG
Conductor MaterialTC - Tinned Copper
Conductor notesFinely Stranded Tinned Copper optomized for VFD use
Ground wiresYes
Number of ground wires3 Wire
Ground construction1/0AWG symmetrical segmented ground (3 of 4AWG)
Segmented ground wire size4 AWG
Segmented ground wire materialBC - Bare Copper
Segmented ground notesSegmented grounds (3 totaling 1/0)
Ground wireNo Insulation
Nom. thickness0.057 in (1.4 mm)
Nom. insulation diameter0.501 in (12.7 mm)
ShieldShielded
Shield TypeCopper tape
Outer shield typeHelical tape
Coverage100%
Shield notes2 mil helical copper tape for crack resistance and high frequency noise conduction
Jacket MaterialPVC - Polyvinyl Chloride
Jacket ColorBlack
Nom. jacket thickness0.083 in (2.1 mm)
Nom. diameter1.258 in (31.95 mm)
Overall cable diameter (nominal)1.258 in (31.95 mm)
RipcordYes
ArmorNo
CompositeNo
Voltage range1KV
Nom. Conductor DCR (Conductor(s))0.094 Ohm/1000ft (0.31 Ohm/km)
Nom. conductor DCR (segmented ground wire)0.09 Ohm/1000ft (0.30 Ohm/km)
Nom. outer shield DCR0.40 Ohm/1000ft (1.3 Ohm/km)
Nom. capacitance cond-to-cond37 pF/ft (120 pF/m)
Nom. capacitance cond-to-other (conds + Shield)67 pF/ft (220 pF/m)
Nom. characteristic impedence50 Ohm
Nom. inductance cond-grnd0.072 µH/ft
Nom. velocity of prop.55%
Max. current170 Amps per Conductor at 30ºC
Stationary min. bend radius15.1 in (384 mm)
Installation min. bend radius15.1 in (384 mm)
Max Pull Tension5530 lbs (2510 kg)
Bulk cable weight1708 lbs/1000ft (2542 kg/km)
NEC / UL complianceArticle 336, TC-ER, WTTC, XHHW-2, UL Flexible Motor Supply Cable
CEC / C(UL) complianceTC
ICEA complianceS-95-658
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)P-07-KA070003-MSHA
SustainabilityCA Prop 65
Ratings & Markings600/1000V TC-ER 90C Dry/Wet 1000V Flexible Motor Supply Cable WTTC 1000V CSA AWM I/II A/B 600V RW90 TC SUN RES DIR BUR Oil Resistant
Other Part Numbers29529 010, 29529 010100, 29529 010250, 29529 010500, 29529 0101000
Priced PerFT

Documenti

Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.

Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?

Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.