Belden 3076F 006 Fieldbus cavo 1 Pr 18 AWG TC CMG

SKU:Belden 3076F 006
$279.60
● Disponibile
Descrizione
Belden 3076F 006 Fieldbus cavo presenta 1 coppia di conduttori in rame stagnato da 18 AWG cordato (7x26) con isolamento in polipropilene (PP). Include un schermatura Beldfoil® + filo di scarico e una PVC guainaazzurro chiaro. Le tensioni includono 300 V (CM, PLTC-ER) e 150 V (ITC), ed è omologata per CMG.
Applicazioni
- Utilizzo in installazioni Fieldbus dove è necessario un schermato cavo per supportare la trasmissione del segnale.
- Scegli progetti che richiedono un cavo certificato CMG per soddisfare i requisiti di installazione.
- Installa in sistemi che specificano tensioni di 300 V (CM, PLTC-ER) o 150 V (ITC).
Specifiche
| Attribute | Value |
|---|---|
| Number of elements | 1 pair |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PP - Polypropylene |
| Nom. thickness (insulation) | 0.022 in (0.56 mm) |
| Nom. insulation diameter | 0.088 in (2.2 mm) |
| Color Code | Blue & Orange |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (7x28) TC |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. thickness (jacket) | 0.050 in (1.3 mm) |
| Overall cable diameter (nominal) | 0.280 in (7.11 mm) |
| Jacket OD +/- | 0.010 |
| Jacket Color | Blue |
| Bulk cable weight | 44 lbs/1000ft |
| Nom. conductor DCR | 7.2 Ohm/1000ft |
| Nom. outer shield DCR | 8.5 Ohm/1000ft (28 Ohm/km) |
| Nom. capacitance (Cond-to-Shield) | 45 pF/ft (150 pF/m) |
| Max. capacitance unbalance | 1.2 pF/ft |
| Nom. characteristic impedence | 100 Ohm |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 5.2 Amps per Conductor at 25ºC |
| Nom. insertion loss (attenuation) | 0.08 dB/100ft at 0.039 MHz |
| UL Voltage Rating | 300 V (CM, PLTC-ER), 150 V (ITC-ER) |
| UL temperature | 105°C |
| Operating temperature | -40°C to +105°C |
| Stationary min. bend radius | 6.5 in (170 mm) |
| Installation min. bend radius | 2.80 in (71.1 mm) |
| Max Pull Tension | 60 lbs (27 kg) |
| Environmental suitability | Indoor, Outdoor, Sunlight Resistance, Oil Resistance, Oil Resistance, Burial |
| Flammability / reaction to fire | UL 1685 UL Loading, FT4, IEEE 1202, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 725, Article 727, Article 800, CMG, ITC, PLTC, TC |
| CEC / C(UL) compliance | CMG |
| ISO/IEC compliance | IEC 61158-2 |
| Other standard compliance(s) | ISA/SP-50 Type A |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Item Type | Belden Multi-Pair Cable |
| Other Part Numbers | 3076F 006, 3076F 006100, 3076F 006250, 3076F 006500, 3076F 0061000 |
| Priced Per | FT |