Belden 5140F1 010, 1 FS PR 14 AWG Multi Conductor PVC PVC Black

SKU:Belden 5140F1 010
● Disponibile
Descrizione
Belden 5140F1 010 is a security & sound cable with 1 pair of 14 AWG stranded TC - Tinned Copper conductors and PVC - Polyvinyl Chloride insulation. It features a Bi-Laminate (Alum+Poly) tape shield with 100% coverage, along with a 16 AWG (19x29) TC drainwire and Waterblock Tape for moisture protection. Rated-CL3-FPL-PLTC and UL 300 V (CL3, FPL, PLTC-ER), it is specified for Indoor/Outdoor, Sunlight Resistance, and Burial environments.
Key Features
- It uses a 1 pair construction with 14 AWG stranded TC - Tinned Copper conductors (19x26).
- PVC - Polyvinyl Chloride insulation is color coded Black & Red.
- A Bi-Laminate (Alum+Poly) tape shield provides 100% coverage for noise immunity.
- It includes a 16 AWG (19x29) TC drainwire and Waterblock Tape for wet or below-grade duct environments.
- Rated-CL3-FPL-PLTC and UL 300 V (CL3, FPL, PLTC-ER).
Technical Specs
Construction & Materials
| Elements | Pair(s) |
|---|---|
| No. of elements | 1 |
| Insulation thickness (nom.) | 0.014 in (0.36 mm) |
| Insulation diameter (nom.) | 0.104 in (2.64 mm) |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall diameter (nom.) | 0.326 in (8.28 mm) |
Electrical Characteristics
| Nom. Conductor DCR | 3.05 Ohm/1000ft (10.0 Ohm/km) |
|---|---|
| Nom. capacitance Cond-to-Cond | 83 pF/ft (270 pF/m) |
| Max. current | 29 Amps per Conductor @ 30°C |
| Nom outer Shield DCR | 4.18 Ohm/1000ft (13.7 Ohm/km) |
Temperature, Mechanical & Handling
| UL temperature | 90°C |
|---|---|
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 3.3 in (84 mm) |
| Bend radius (installation min.) | 3.3 in (84 mm) |
| Max. pull tension | 135 lbs (61.2 kg) |
| Bulk cable weight | 61 lbs/1000ft (91 kg/km) |
Compliance, Fire Ratings & Directives
| NEC / UL compliance | Article 725, Article 760, Article 800, CL3, FPL, PLTC |
|---|---|
| CEC / C(UL) compliance | CL3 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR Euroclass | Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Environmental & Sustainability
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
|---|---|
| Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
Applications
- It is designed for security system wiring where shielded construction and moisture protection are needed.
- Intercom/PA installations can benefit from its noise immunity.
- Audio/speaker runs may use shielding to help reduce interference.
- It is specified for Fire Alarm (Red Jkt) applications.
- Power-limited controls can use it where CL3/FPL/PLTC ratings are required.
- Noisy & wet location installations are supported.
- Below-grade duct routing is appropriate where Waterblock Tape is specified.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Elements | Pair(s) |
| No. of elements | 1 |
| Insulation thickness (nom.) | 0.014 in (0.36 mm) |
| Insulation diameter (nom.) | 0.104 in (2.64 mm) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket thickness (nom.) | 0.042 in (1.1 mm) |
| Overall diameter (Nom.) | 0.326 in (8.28 mm) |
| Nom. conductor DCR | 3.05 Ohm/1000ft (10.0 Ohm/km) |
| Nom. capacitance cond-to-cond | 83 pF/ft (270 pF/m) |
| Max. current | 29 Amps per Conductor @ 30°C |
| Nom. outer shield DCR | 4.18 Ohm/1000ft (13.7 Ohm/km) |
| UL temperature | 90°C |
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 3.3 in (84 mm) |
| Bend radius (installation min.) | 3.3 in (84 mm) |
| Max Pull Tension | 135 lbs (61.2 kg) |
| Bulk cable weight | 61 lbs/1000ft (91 kg/km) |
| NEC / UL compliance | Article 725, Article 760, Article 800, CL3, FPL, PLTC |
| CEC / C(UL) compliance | CL3 |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEEE 1202 FT4, IEC 60332-1-2 |
| CPR Euroclass | Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Environmental suitability | Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Burial |
| Sustainability | Product Lens™, Environmental Product Declaration (EPD) Available |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.