Belden 5584G1 008, Multi Conductor 1 FS PR 2 Pair 22 AWG PVC Gray

SKU:Belden 5584G1 008
● Disponibile
Descrizione
Belden 5584G1 008 is a rated-CM security & sound cable with 22 AWG solid tinned copper conductors, PVC insulation, and a PVC jacket. It includes 1 pair protected by a Beldfoil® tape shield and drain wire, along with 2 additional unshielded pairs. Inner and overall waterblocking tape and a 300 V rating support use in security systems, intercom/PA, audio/speaker, and power-limited control circuits, including noisy & wet locations and below-grade duct installations.
Key Features
- Rated-CM security & sound cable for security systems, intercom/PA, audio/speaker, and power-limited control circuits.
- 22 AWG solid tinned copper conductors with PVC insulation.
- 1 pair with Beldfoil® tape shield and drain wire, plus 2 additional unshielded pairs.
- Inner and overall waterblocking tape for noisy & wet locations and below-grade duct installations.
- PVC jacket with UL voltage rating: 300 V.
Technical Specs
Construction & Materials
| Conductor material | TC - Tinned Copper |
|---|---|
| Conductor size | 22 AWG |
| Conductor type | Solid |
| Pairs | 1 x 22 AWG (Solid) TC - Tinned Copper |
| Pairs | 2 x 22 AWG (Solid) TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.01 in (0.25 mm) |
| Nom. insulation diameter | 0.046 in (1.2 mm) |
| Color code (pair) | Black & Red |
| Color code (pairs) | Black & White, Black & Green |
| Inner shield (Blk/Red pair) | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Shield coverage | 100% |
| Drainwire type | 20 AWG (Solid) TC |
| Outer shield | No Shield |
| Jacket material | PVC - Polyvinyl Chloride |
| Separator | Waterblocking Tape |
| Ripcord | Yes |
Dimensions & Physical Specs
| Nom. jacket thickness | 0.025 in (0.64 mm) |
|---|---|
| Overall cable diameter (nominal) | 0.283 in |
| Bulk cable weight | 31.7 lbs/1000ft |
Environmental & Mechanical Ratings
| UL temperature | 105°C |
|---|---|
| Operating | -20°C To +105°C |
| Bend radius (stationary min.) | 2.83 in (71.9 mm) |
| Bend radius (installation min.) | 2.83 in |
| Max. pull tension | 59 lbs (27 kg) |
| Environmental suitability | Indoor |
Performance & Electrical Characteristics
| Nom. conductor DCR (pair) | 20.6 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond (pair) | 33 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (Conds + Shield) (pair) | 58.6 pF/ft (192 pF/m) |
| Max. current | 3.2 Amps per Conductor at 25ºC |
| Nom. conductor DCR (pair) | 20.6 Ohm/1000ft (67.6 Ohm/km) |
| Nom. capacitance cond-to-cond (pair) | 18 pF/ft (59 pF/m) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
|---|---|
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
Applications
- Use in security system installations where a rated-CM security & sound cable is required.
- Run intercom/PA wiring in indoor environments.
- Support audio/speaker connections that benefit from a shielded pair and additional unshielded pairs in one cable.
- Install in power-limited controls circuits for indoor applications.
- Route through noisy & wet locations where waterblocking tape is desired.
- Specify for below-grade duct installations where waterblocking tape is required.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Conductor Material | TC - Tinned Copper |
| Conductor size | 22 AWG |
| Conductor Type | Solid |
| Pairs | 1 x 22 AWG (Solid) TC - Tinned Copper; 2 x 22 AWG (Solid) TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.01 in (0.25 mm) |
| Nom. insulation diameter | 0.046 in (1.2 mm) |
| Color code (pair) | Black & Red |
| Color Code (pairs) | Black & White, Black & Green |
| Inner shield (Blk/Red pair) | Tape |
| Inner shield material | Bi-Laminate (Alum+Poly) |
| Shield Coverage | 100% |
| Drainwire type | 20 AWG (Solid) TC |
| Outer shield | No Shield |
| Jacket Material | PVC - Polyvinyl Chloride |
| Separator | Waterblocking Tape |
| Ripcord | Yes |
| Nom. jacket thickness | 0.025 in (0.64 mm) |
| Overall cable diameter (nominal) | 0.283 in |
| Bulk cable weight | 31.7 lbs/1000ft |
| UL temperature | 105°C |
| Operating | -20°C To +105°C |
| Bend radius (stationary min.) | 2.83 in (71.9 mm) |
| Bend radius (installation min.) | 2.83 in |
| Max Pull Tension | 59 lbs (27 kg) |
| Environmental suitability | Indoor |
| Nom. conductor DCR (pair) | 20.6 Ohm/1000ft; 20.6 Ohm/1000ft (67.6 Ohm/km) |
| Nom. capacitance cond-to-cond (pair) | 33 pF/ft (110 pF/m); 18 pF/ft (59 pF/m) |
| Nom. capacitance cond-to-other (Conds + Shield) (pair) | 58.6 pF/ft (192 pF/m) |
| Max. current | 3.2 Amps per Conductor at 25ºC |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 800, CM |
| CEC / C(UL) compliance | CM |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.