Belden 6100UE 009U is a security and commercial audio cable for intercom/PA systems and sound/audio systems in plenum spaces. It features a 2-conductor 14 AWG stranded bare copper (BC) design with Flamarrest® insulation and a Flamarrest® jacket, plus a ripcord for easier stripping. This cable meets Plenum-CL2P requirements and is rated 75°C and 300 V, with max. current of 25 Amps per Conductor @ 25°C.
Key Features
- 2 conductors of 14 AWG stranded bare copper (BC) for security and commercial audio wiring.
- Flamarrest® insulation and Flamarrest® jacket for plenum installations.
- Plenum-CL2P construction with NEC / UL compliance: Article 725, CL2P.
- Rated 75°C and 300 V.
- Includes a ripcord for easier stripping.
Technical Specs
Construction & Materials
| Number of Conductors | 2 |
| Conductor Size | 14 AWG |
| Conductor Material | BC - Bare Copper |
| Conductor Type | Stranded Conductor |
| Stranding | 19x26 |
| Insulation Material | PVC - Polyvinyl Chloride |
| Insulation Nom. Thickness | 0.010 in (0.25 mm) |
| Nom. Insulation Diameter | 0.090 in (2.3 mm) |
| Color Code | Black, White |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket Nom. Thickness | 0.015 in (0.38 mm) |
Physical & Mechanical Specs
| Nom. Diameter | 0.210 in (5.33 mm) |
| Overall Cable Diameter (nominal) | 0.210 in (5.33 mm) |
| Max. Pull Tension | 95 lbs (43 kg) |
| Bulk Cable Weight | 35 lbs/1000ft |
| Bend Radius (stationary min.) | 2.1 in (53 mm) |
| Bend Radius (installation min.) | 2.1 in (53 mm) |
Performance & Electrical Characteristics
| Nom. Conductor DCR | 2.54 Ohm/1000ft |
| Nom. Capacitance Cond-to-Cond | 36 pF/ft (120 pF/m) |
| Nom. Inductance | 0.145 μH/ft (0.476 μH/m) |
Environmental & Temperature Ratings
| Operating Temperature | 0°C to +75°C |
| Installation Temperature | 0°C to +75 |
| Environmental Suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), IEC 60332-1-2 |
| CPR Euroclass | Eca |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK Regulation Compliance | UKCA Mark |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
Applications
- Use in intercom/PA systems where plenum-space routing is required.
- Install in sound/audio systems within indoor plenum environments.
Belden™ and all associated trademarks are the property of their respective owners.