Belden 6300FE 877, Commercial Audio Cable 2C 18 AWG FLRST FS Natural

SKU:Belden 6300FE 877
● Disponibile
Descrizione
Belden 6300FE 877 is a Plenum-CMP security & commercial audio cable with 2-18 AWG stranded bare copper conductors and PVC - Polyvinyl Chloride insulation. It includes an overall Beldfoil® tape shield (foil side out) with a drain wire to support noise rejection in signal runs. A PVC - Polyvinyl Chloride jacket with ripcord helps with pulling and stripping, and sequential footage marking every two feet supports installation accuracy. UL Voltage Rating is 300 V and UL temperature is 75°C.
Key Features
- Plenum-CMP cable construction for indoor - plenum and indoor environments.
- 2 conductors with 18 AWG size and 7x26 stranding.
- BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation.
- Overall Beldfoil® tape shield (foil side out) with 100% coverage and a drain wire.
- PVC - Polyvinyl Chloride jacket with ripcord for easier pulls and stripping.
- Sequential footage marking every two feet to help with measuring and layout.
Technical Specs
Construction & Materials
| Conductor material | BC - Bare Copper |
|---|---|
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.063 in (1.6 mm) |
| Color code | Black, Red |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nom.) | 0.162 in (4.11 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
Electrical Characteristics
| UL Voltage Rating | 300 V |
|---|---|
| Nom. Conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance Cond-to-Cond | 70 pF/ft (230 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 μH/ft (0.49 μH/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom outer Shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating | 0°C to +75°C |
| Stationary min. bend radius | 1.6 in (41 mm) |
| Installation min. bend radius | 1.6 in (41 mm) |
| Max. pull tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
Compliance & Certifications
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
|---|---|
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-Plenum number | 5300FH |
|---|
Applications
- Use in security system installations where shielded signal cabling is needed in indoor - plenum or indoor spaces.
- Support intercom/PA wiring runs that benefit from an overall shield and drain wire in building interiors.
- Choose for audio/speaker connections requiring a 2-conductor cable with consistent identification and footage marking.
- Install in noisy environment locations where the overall Beldfoil® tape shield and drain wire can help manage interference.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Conductor Material | BC - Bare Copper |
| Insulation thickness (nom.) | 0.009 in (0.23 mm) |
| Insulation diameter (nom.) | 0.063 in (1.6 mm) |
| Color Code | Black, Red |
| Jacket thickness (nom.) | 0.015 in (0.38 mm) |
| Overall cable diameter (nom.) | 0.162 in (4.11 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 6.4 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 70 pF/ft (230 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 126 pF/ft (413 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Max. current | 14 Amps per Conductor @ 25°C |
| Nom. outer shield DCR | 15.9 Ohm/1000ft (52.2 Ohm/km) |
| UL temperature | 75°C |
| Operating | 0°C to +75°C |
| Stationary min. bend radius | 1.6 in (41 mm) |
| Installation min. bend radius | 1.6 in (41 mm) |
| Max Pull Tension | 50.3 lbs (22.8 kg) |
| Bulk cable weight | 21 lbs/1000ft |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5300FH |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.