Belden 6306UE 877, Multi Conductor 8C 18 AWG FLRST Natural

SKU:Belden 6306UE 877
● Disponibile
Descrizione
Belden 6306UE 877 is a plenum-rated security & sound cable with 8 stranded 18 AWG BC - Bare Copper conductors. It features Flamarrest® insulation and a Flamarrest® jacket for indoor plenum installations where low-smoke, flame-retardant performance is required. A ripcord supports easier jacket removal, and sequential footage marking every two feet helps simplify measuring and pulls.
Key Features
- Plenum-rated cable for Indoor - Plenum, Indoor environments.
- 8 conductors with 18 AWG stranded construction (7x26).
- BC - Bare Copper conductors with PVC - Polyvinyl Chloride insulation and a PVC - Polyvinyl Chloride outer jacket.
- Ripcord included for easier jacket removal.
- Sequential footage marking every two feet to support measuring and pulls.
Technical Specs
Construction & Materials
| Number of Conductors | 8 |
|---|---|
| Conductor Size | 18 AWG |
| Conductor Stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. Insulation Thickness | 0.009 in (0.23 mm) |
| Nom. Insulation Diameter | 0.063 in (1.6 mm) |
| Color Code | Black, Red, White, Green, Brown, Blue, Orange, Yellow |
| Outer Jacket Material | PVC - Polyvinyl Chloride |
| Nom. Jacket Thickness | 0.015 in (0.38 mm) |
| Overall Cable Diameter (nominal) | 0.235 in (5.97 mm) |
Electrical Characteristics
| UL Voltage Rating | 300 V |
|---|---|
| Nom. Conductor DCR | 6.5 Ohm/1000ft |
| Nom. Capacitance Cond-to-Cond | 34 pF/ft (110 pF/m) |
| Max. Current | 9.8 Amps per Conductor @ 25°C |
Environmental & Mechanical Ratings
| UL Temperature | 75°C |
|---|---|
| Operating Temperature | 0°C to +75°C |
| Bend Radius (stationary min.) | 2.4 in (61 mm) |
| Bend Radius (installation min.) | 2.4 in (61 mm) |
| Max. Pull Tension | 179 lbs (81.2 kg) |
| Bulk Cable Weight | 56 lbs/1000ft |
| Environmental Suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| Flammability / Reaction to Fire | NFPA 262, UL 910 (Plenum), FT6 |
|---|---|
| NEC / UL Compliance | Article 800, CMP |
| CEC / C(UL) Compliance | CMP |
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Related Part Reference
| Non-Plenum Number | 5306UE |
|---|
Applications
- Use in security system installations where signal and power-limited circuits are required.
- Support intercom/PA systems that distribute audio and control signals.
- Run audio/speaker lines in indoor building spaces that require plenum-rated cabling.
- Install for power-limited controls wiring in indoor control circuits.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Number of Conductors | 8 |
| Conductor size | 18 AWG |
| Conductor stranding | 7x26 |
| Conductor Material | BC - Bare Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.009 in (0.23 mm) |
| Nom. insulation diameter | 0.063 in (1.6 mm) |
| Color Code | Black, Red, White, Green, Brown, Blue, Orange, Yellow |
| Outer jacket material | PVC - Polyvinyl Chloride |
| Nom. jacket thickness | 0.015 in (0.38 mm) |
| Overall cable diameter (nominal) | 0.235 in (5.97 mm) |
| UL Voltage Rating | 300 V |
| Nom. conductor DCR | 6.5 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Max. current | 9.8 Amps per Conductor @ 25°C |
| UL temperature | 75°C |
| Operating temperature | 0°C to +75°C |
| Bend radius (stationary min.) | 2.4 in (61 mm) |
| Bend radius (installation min.) | 2.4 in (61 mm) |
| Max Pull Tension | 179 lbs (81.2 kg) |
| Bulk cable weight | 56 lbs/1000ft |
| Environmental suitability | Indoor - Plenum, Indoor |
| Flammability / reaction to fire | NFPA 262, UL 910 (Plenum), FT6 |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Non-Plenum number | 5306UE |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.