Belden 8268 010 RG-214 13 AWG 7x21 Treccia in rame argentato Guaina PVC

Descrizione
Il cavo coassiale Mil-Spec Belden 8268 010 RG-214 è un cavo da 50 Ohm con conduttore in rame argentato 13 AWG (7x21), isolamento in PE, doppia treccia di schermatura in rame argentato al 95% e guaina in PVC (Non-Contaminating). Rating: CMX. Classificazione: Commercial, Non-QPL.
Applicazioni
- Da utilizzare quando è richiesto un cavo coassiale Mil-Spec con impedenza di 50 Ohm.
- Adatto per installazioni che specificano RG-214 per la connettività coassiale.
- Selezionare per realizzazioni commerciali che richiedono un cavo Non-QPL.
Specifiche
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Nom. conductor diameter | 0.089 in |
| Nom. insulation diameter | 0.285 in (7.24 mm) |
| Insulation color code | White |
| Overall cable diameter (nominal) | 0.425 in (10.8 mm) |
| Bulk cable weight | 131 lbs/1000ft |
| Nom. velocity of prop. | 66% |
| Nom. capacitance (Cond-to-Shield) | 30.8 pF/ft (101 pF/m) |
| Nom. conductor DCR | 1.7 Ohm/1000ft |
| Nom. outer shield DCR | 0.7 Ohm/1000ft (2.3 Ohm/km) |
| UL Voltage Rating | 300 V (CMX), 30 V (UL AWM 1354) |
| Voltage Rating | 3700 V (Mil-Spec) |
| Attenuation (nominal) 1 MHz | 0.17 dB/100ft |
| Attenuation (nominal) 10 MHz | 0.55 dB/100ft |
| Attenuation (nominal) 50 MHz | 1.3 dB/100ft |
| Attenuation (nominal) 100 MHz | 1.9 dB/100ft |
| Attenuation (nominal) 200 MHz | 2.7 dB/100ft |
| Attenuation (nominal) 400 MHz | 4.1 dB/100ft |
| Attenuation (nominal) 700 MHz | 6.5 dB/100ft |
| Attenuation (nominal) 900 MHz | 7.6 dB/100ft |
| Attenuation (nominal) 1000 MHz | 8.0 dB/100ft |
| Attenuation (nominal) 4000 MHz | 20.0 dB/100ft |
| Power rating (max.) 50 MHz | 1,500 W |
| Power rating (Max.) 100 MHz | 907 W |
| Power rating (Max.) 200 MHz | 549 W |
| Power rating (Max.) 400 MHz | 332 W |
| Power rating (Max.) 700 MHz | 221 W |
| Power rating (max.) 900 MHz | 184 W |
| Power rating (Max.) @ 1,000 MHz | 171 W |
| Power rating (max.) 4,000 MHz | 62 W |
| UL temperature | 60°C (UL AWM 1354) |
| Operating temperature | -40°C to +80°C |
| Installation min. bend radius | 4.25 in (108 mm) |
| Max Pull Tension | 225 lbs (102 kg) |
| NEC / UL compliance | CMX |
| CEC / C(UL) compliance | CMX |
| AWM compliance | AWM 1354 |
| Flammability / reaction to fire | VW-1 |
| CPR compliance | CPR Euroclass: Eca |
| Military compliance | Commercial, non-QPL product (M17/164-00001) |
| Sustainability | CA Prop 65 |
| European directive compliance | EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Item Type | Belden Coaxial Cable |
| Other Part Numbers | 8268 010100; 8268 010250; 8268 010500; 8268 0101000 |
| Priced Per | FT |
Documenti
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.