Belden 8771 060, Multi Conductor Cable 3C 22 AWG PE PVC Jacket

SKU:Belden 8771 060
● Disponibile
Descrizione
Belden 8771 060 is a 3 conductor 22 AWG multi-conductor cable for low voltage signal and control wiring. It features stranded (7x30) TC - tinned copper conductors with PE - polyethylene insulation and an overall Beldfoil® shield with 100% coverage plus a 22 AWG (7x30) TC drainwire. The PVC - polyvinyl chloride outer jacket is rated CM for indoor installations. Electrical characteristics include 17.8 Ohm/1000ft Nom. Conductor DCR and a UL voltage rating of 300 V (CM), 300 V (UL AWM 2093).
Belden 8771 060 Key Features
- This cable uses a 3 conductor 22 AWG construction with stranded (7x30) TC - tinned copper conductors.
- It includes an overall Beldfoil® shield with 100% coverage and a 22 AWG (7x30) TC drainwire.
- PE - polyethylene insulation is color coded: Black, Red, Clear.
- The PVC - polyvinyl chloride outer jacket is CM rated for indoor use.
- UL voltage rating: 300 V (CM), 300 V (UL AWM 2093).
Belden 8771 060 Technical Specs
Construction & Physical Specs
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
|---|---|
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nominal) | 0.199 in (5.05 mm) |
| Bulk cable weight | 22 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. capacitance Cond-to-Cond | 23 pF/ft (75 pF/m) |
|---|---|
| Nom. capacitance Cond-to-other (conds + Shield) | 41 pF/ft (130 pF/m) |
| Max. current | 6 Amps per Conductor at 30ºC |
| Nom outer Shield DCR | 12.86 Ohm/1000ft (42.19 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 60°C |
|---|---|
| Operating | -20°C to +60°C |
| Bend radius (stationary min.) | 0.56 in (14 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max. pull tension | 36.4 lbs (16.5 kg) |
| Environmental suitability | Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| AWM compliance | AWM 2093 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 8771 060 Applications
- It supports low voltage analog signals such as 4-20ma and 0-10v in signal and control wiring runs.
- For low voltage control circuits, it is suitable for 24v control where consistent signal wiring is needed.
- In indoor installations, it is commonly used for line level audio and voice communications wiring.
- For panel wiring, it fits applications where a multi-conductor, shielded construction is specified.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Insulation thickness (nom.) | 0.017 in (0.43 mm) |
| Insulation diameter (nom.) | 0.062 in (1.6 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Jacket thickness (nom.) | 0.033 in (0.84 mm) |
| Overall cable diameter (nominal) | 0.199 in (5.05 mm) |
| Bulk cable weight | 22 lbs/1000ft |
| Nom. capacitance cond-to-cond | 23 pF/ft (75 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 41 pF/ft (130 pF/m) |
| Max. current | 6 Amps per Conductor at 30ºC |
| Nom. outer shield DCR | 12.86 Ohm/1000ft (42.19 Ohm/km) |
| UL temperature | 60°C |
| Operating | -20°C to +60°C |
| Bend radius (stationary min.) | 0.56 in (14 mm) |
| Bend radius (installation min.) | 2.0 in (51 mm) |
| Max Pull Tension | 36.4 lbs (16.5 kg) |
| Environmental suitability | Indoor |
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2093 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.