Belden 9502 060, Multi Conductor Computer Cable 2 pair 24 AWG PVC

SKU:Belden 9502 060
● Disponibile
Descrizione
Belden 9502 060 is a 2 twisted pair computer EIA RS-232 cable with 24 AWG stranded (7x32) TC - Tinned Copper conductors, semi-rigid PVC insulation, and a PVC jacket. It features an overall Beldfoil® shield (100% coverage) with a 24 AWG (7x32) TC drainwire to help reduce EMI in noise-sensitive installations. The cable has a nominal 0.222 in (5.64 mm) overall diameter and is designed for indoor use.
Belden 9502 060 Key Features
- 2 twisted pair computer EIA RS-232 cable construction for data and control signal wiring.
- 24 AWG stranded (7x32) TC - Tinned Copper conductors.
- Semi-rigid PVC insulation (SR-PVC - Polyvinyl Chloride (Semi-Rigid)).
- Overall Beldfoil® shield with 100% coverage and a 24 AWG (7x32) TC drainwire.
- PVC - Polyvinyl Chloride jacket with a nominal 0.222 in (5.64 mm) overall diameter.
- UL voltage rating: 300 V (CMG), 300 V (UL AWM 2464).
- Operating temperature: -30°C to +80°C.
- Environmental suitability: indoor.
Belden 9502 060 Technical Specs
Construction & Materials
| Pairs | 2 |
|---|---|
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor material | TC - Tinned Copper |
| Color code | Black & Red, Black & White |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
Physical Dimensions
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
|---|---|
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
Performance & Electrical Characteristics
| Nom. Conductor DCR | 28.8 Ohm/1000ft |
|---|---|
| Nom. capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance Cond-to-other (conds + Shield) | 50 pF/ft (160 pF/m) |
| Nom. inductance | 0.19 μH/ft (0.62 μH/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 2.1 Amps per Conductor at 25ºC |
| Nom outer Shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 80°C |
|---|---|
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max. pull tension | 27.5 lbs (12.5 kg) |
| Bulk cable weight | 26 lbs/1000ft |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4 |
|---|---|
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464, AWM I/II A |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-7K-182037 |
| Plenum number | 82502 |
Belden 9502 060 Applications
- RS-232 applications are commonly supported where consistent low-voltage signal transmission is required.
- Computer communications links can be supported in installations that require a shielded twisted-pair construction.
- Control and instrumentation wiring often uses low voltage analog signals (4-20ma, 0-10v, ...).
- Equipment and systems can support low voltage digital control (24v, …) connections for control signaling.
- Noise-sensitive routing can use line level audio runs where a shielded cable is preferred.
- Organized internal routing and terminations are commonly supported in panel wiring.
Belden™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Pairs | 2 |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Color Code | Black & Red, Black & White |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Drainwire type | 24 AWG (7x32) TC |
| Insulation thickness (nom.) | 0.011 in (0.28 mm) |
| Insulation diameter (nom.) | 0.044 in (1.1 mm) |
| Jacket thickness (nom.) | 0.032 in (0.81 mm) |
| Nom. conductor DCR | 28.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 50 pF/ft (160 pF/m) |
| Nom. inductance | 0.19 µH/ft (0.62 µH/m) |
| Nom. velocity of prop. | 60% |
| Max. current | 2.1 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 16.19 Ohm/1000ft (53.12 Ohm/km) |
| UL temperature | 80°C |
| Bend radius (stationary min.) | 2.2 in (56 mm) |
| Bend radius (installation min.) | 2.2 in (56 mm) |
| Max Pull Tension | 27.5 lbs (12.5 kg) |
| Bulk cable weight | 26 lbs/1000ft |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMG |
| AWM compliance | AWM 2464, AWM I/II A |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | P-MSHA-SC-7K-182037 |
| Plenum number | 82502 |
| Priced Per | FT |