Belden BAV 1862A D26, Speaker Cable 16 AWG TW PR Black Natural

SKU:Belden 1862A D26
● Disponibile
Descrizione
Belden BAV 1862A D26 is a 2 conductor speaker cable built with 16 AWG stranded (19x29) BC - Bare Copper conductors and Flamarrest® insulation. It features an open twisted construction and is designed for Indoor - Plenum, Indoor environments. This cable meets CL3P requirements, is rated to NFPA 262, and has a UL voltage rating of 150 V RMS.
Technical Specs
Construction & Materials
| Number of conductors | 2 Conductor |
|---|---|
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor material | BC - Bare Copper |
| Conductor type | Stranded |
| Insulation | Flamarrest® Insulation |
| Insulation material | PVC - Polyvinyl Chloride |
| Cabling | Open twisted construction |
| Outer shield | No Shield |
Electrical & Physical Specs
| Outer jacket nominal diameter | 0.202 in |
|---|---|
| UL voltage rating | 150 V RMS |
| Bulk cable weight | 24 lbs/1000ft (36 kg/km) |
Environmental & Mechanical Ratings
| Operating temperature | -20°C To +75°C |
|---|---|
| Max. pull tension | 60.8 lbs (27.6 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| NEC / UL compliance | CL3P |
|---|---|
| Flammability / reaction to fire | NFPA 262 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use in speaker cable installations where CL3P and NFPA 262 requirements apply.
- Ideal for Indoor - Plenum, Indoor speaker runs in commercial and institutional wiring environments.
Belden BAV™ and all associated trademarks are the property of their respective owners.
Specifiche
| Attribute | Value |
|---|---|
| Number of Conductors | 2 Conductor |
| Conductor size | 16 AWG |
| Conductor stranding | 19x29 |
| Conductor Material | BC - Bare Copper |
| Conductor Type | Stranded |
| Insulation | Flamarrest® Insulation |
| Insulation Material | PVC - Polyvinyl Chloride |
| Cabling | Open twisted construction |
| Outer shield | No Shield |
| Outer jacket nominal diameter | 0.202 in |
| UL Voltage Rating | 150 V RMS |
| Bulk cable weight | 24 lbs/1000ft (36 kg/km) |
| Operating temperature | -20°C To +75°C |
| Max Pull Tension | 60.8 lbs (27.6 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| NEC / UL compliance | CL3P |
| Flammability / reaction to fire | NFPA 262 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
Le immagini sono solo di riferimento. Le specifiche possono cambiare senza preavviso — verificare l'idoneità alla propria applicazione prima dell'acquisto. La documentazione del produttore prevale.
Hai bisogno di un taglio su misura, prezzi all'ingrosso o una scheda tecnica?
Il nostro team prepara preventivi per lunghezze personalizzate e ordini all'ingrosso, di solito in giornata.