Contato1-800-975-3686
Ramcorp Wire & Cable

Belden 1189A 010, Coax Broadband CATV Cable 18 AWG DBL SH PVC

Belden 1189A 010, Coax Broadband CATV Cable 18 AWG DBL SH PVC

SKU:Belden 1189A 010

$350.00

Em estoque

Descrição

Especificações

Belden 1189A 010, Coax Broadband CATV Cable 18 AWG DBL SH PVC specifications
AttributeValue
Color CodeWhite
Nom. jacket diameter0.294 in (7.47 mm)
Outer shield layer 1Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100%
Outer shield layer 2Braid, Aluminum, 60%
Outer shield layer 3Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%
Outer shield layer 4Braid, Aluminum, 40%
Nom. characteristic impedance75 Ohm
Nom. velocity of prop.83%
Nom. capacitance (Cond-to-Shield)16.2 pF/ft (53.1 pF/m)
Nom. conductor DCR28 Ohm/1000ft
Nom. outer shield DCR4.8 Ohm/1000ft (16 Ohm/km)
Return loss 5-1000 MHz20 dB min. structural return loss
Attenuation max. at 5 MHz0.67 dB/100ft
Attenuation max. at 55 MHz1.60 dB/100ft
Attenuation max. at 211 MHz2.87 dB/100ft
Attenuation max. at 250 MHz3.30 dB/100ft
Attenuation max. at 270 MHz3.24 dB/100ft
Attenuation max. at 300 MHz3.43 dB/100ft
Attenuation max. at 330 MHz3.74 dB/100ft
Attenuation max. at 350 MHz3.72 dB/100ft
Attenuation max. at 400 MHz4.00 dB/100ft
Attenuation max. at 450 MHz4.26 dB/100ft
Attenuation max. at 500 MHz4.66 dB/100ft
Attenuation max. at 550 MHz4.71 dB/100ft
Attenuation max. at 600 MHz5.10 dB/100ft
Attenuation max. at 750 MHz5.59 dB/100ft
Attenuation max. at 870 MHz6.00 dB/100ft
Attenuation max. at 1000 MHz6.54 dB/100ft
Operating temperature-40°C to +80°C
Installation min. bend radius2.9 in (74 mm)
Max Pull Tension176 lbs (79.8 kg)
Bulk cable weight32 lbs/1000ft
Environmental suitabilityIndoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire
CEC / C(UL) complianceCM
Flammability / reaction to fireUL1685 UL Loading
CPR complianceCPR Euroclass: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Other standard compliance(s)ANSI/SCTE 74
SustainabilityCA Prop 65
Plenum number1189AP
Priced PerFT

As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.

Precisa de um corte sob medida, preço por volume ou uma ficha técnica?

Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.