Belden 1505A 003 SDI Coaxial RG-59 20 AWG BC CMR Laranja

Belden 1505A 003 SDI Coaxial RG-59 20 AWG BC CMR Laranja

SKU:Belden 1505A 003

Solicitar cotação

Solicitar cotação

Descrição

Especificações

Belden 1505A 003 SDI Coaxial RG-59 20 AWG BC CMR Laranja specifications
AttributeValue
Coax constructionCoaxial
Coax TypeRG 59
RG type59
Nom. diameter0.032 in
Nom. insulation diameter0.145 in (3.68 mm)
Insulation color codeWhite
Shield TypeBoth, braid over foil
Shield layer 1Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100%
Shield layer 2Braid, Tinned Copper (TC), 95%
FloodedNo not flooded over braid
Jacket diameter (nom.)0.233 in (5.92 mm)
Overall cable diameter (nominal)0.233 in (5.92 mm)
Bulk cable weight31 lbs/1000ft (46 kg/km)
Plenum number1506A
Nom. conductor DCR10 Ohm/1000ft (33 Ohm/km)
Nom. outer shield DCR3.8 Ohm/1000ft (12 Ohm/km)
Nom. capacitance (Cond-to-Shield)16.3 pF/ft (53.5 pF/m)
Nom. velocity of prop.82%
Return loss (5 - 1600 MHz)23 dB
Return loss (1600 - 4500 MHz)21 dB
Return loss (4500 - 6000 MHz)15 dB
Attenuation (nominal) 1 MHz0.3 dB/100ft
Attenuation (Nominal) 3.58 MHz0.6 dB/100ft
Attenuation (Nominal) 5 MHz0.63 dB/100ft
Attenuation (Nominal) 6 MHz0.69 dB/100ft
Attenuation (Nominal) 7 MHz0.74 dB/100ft
Attenuation (nominal) 10 MHz0.9 dB/100ft
Attenuation (Nominal) 12 MHz0.91 dB/100ft
Attenuation (Nominal) 25 MHz1.3 dB/100ft
Attenuation (Nominal) 67.5 MHz2.05 dB/100ft
Attenuation (Nominal) 71.5 MHz2.1 dB/100ft
Attenuation (Nominal) 88.5 MHz2.2 dB/100ft
Attenuation (nominal) 100 MHz2.3 dB/100ft
Attenuation (Nominal) 135 MHz2.7 dB/100ft
Attenuation (Nominal) 143 MHz2.8 dB/100ft
Attenuation (Nominal) 180 MHz3.1 dB/100ft
Attenuation (Nominal) 270 MHz3.8 dB/100ft
Attenuation (Nominal) 360 MHz4.4 dB/100ft
Attenuation (Nominal) 540 MHz5.5 dB/100ft
Attenuation (Nominal) 720 MHz6.4 dB/100ft
Attenuation (Nominal) 750 MHz6.5 dB/100ft
Attenuation (nominal) 1000 MHz7.6 dB/100ft
Attenuation (Nominal) 1500 MHz9.3 dB/100ft
Attenuation (Nominal) 2000 MHz10.9 dB/100ft
Attenuation (Nominal) 2250 MHz11.6 dB/100ft
Attenuation (Nominal) @ 3000 MHz13.4 dB/100ft
Attenuation (Nominal) 4500 MHz17.5 dB/100ft
Attenuation (Nominal) 6000 MHz21.1 dB/100ft
OutdoorNo not outdoor grade material
UL Voltage Rating300 V (CMR, CMG)
UL temperature60°C
Operating temperature-30°C to +75°C
Installation min. bend radius2.3 in (58 mm)
Max Pull Tension52 lbs (24 kg)
Environmental suitabilityIndoor, Indoor, Aerial - Black only, When supported by messenger Wire
NEC / UL complianceCMR
CEC / C(UL) complianceCMG
Fire ratingRiser
Flammability / reaction to fireUL1666 Vertical Shaft
CPR complianceCPR Euroclass: Eca; CPR UKCA Class: Eca
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
SustainabilityCA Prop 65
Item TypeBelden Coaxial Cable RG59
Priced PerFT