Belden 1617A 009, RG11 14 SOLID SS FPE Shield PV White 75 OHM

SKU:Belden 1617A 009
● Em estoque
Descrição
Belden 1617A 009 is a Series 11 RG 11 coaxial cable designed for broadband, CATV, RF drop cable, and Over-The-Air (OTA) antenna runs requiring 75 Ohm performance. It uses a 14 AWG solid BCCS - Bare Copper Covered Steel conductor with PE - Polyethylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. The Quad Shield (F/B+F/B) construction combines foil and aluminum braid layers to help reduce interference. It is CM rated with a UL voltage rating of 300 V (CM) for indoor general-purpose installations.
Key Features
- Series 11 RG 11 coaxial construction for broadband and CATV signal distribution.
- 75 Ohm nominal characteristic impedance for consistent coax performance.
- Quad Shield (F/B+F/B) design with foil and aluminum braid layers to help reduce interference.
- 14 AWG solid BCCS - Bare Copper Covered Steel conductor with PE - Polyethylene (Foam) insulation.
- PVC - Polyvinyl Chloride jacket with CM rating and UL voltage rating of 300 V (CM).
Technical Specs
Product Identification
| Part number | 1617A 009 |
|---|---|
| Brand | Belden |
| Coax type | RG 11 |
| Series type | 11 |
| Plenum number | 1617AP |
Construction & Physical Specs
| Overall cable diameter (nominal) | 0.407 in (10.3 mm) |
|---|---|
| Conductor nominal diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Insulation color code | White |
| Shield type | Quad Shield (F/B+F/B) |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
| Bulk cable weight | 60 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. velocity of prop. | 83% |
|---|---|
| Nom. capacitance Cond-to-Shield | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 3 Ohm/1000ft (9.8 Ohm/km) |
| Return loss | 5 - 1000 MHz: 20 dB (min. structural return loss) |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.60 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
Environmental & Mechanical Ratings
| Operating | -40°C to +75°C |
|---|---|
| UL temperature | 75°C |
| Installation min. bend radius | 4.1 in (100 mm) |
| Max. pull tension | 308 lbs (140 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
Compliance & Certifications
| NEC / UL compliance | CM, CATV |
|---|---|
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
Applications
- Supports broadband distribution where stable coax performance is required.
- Used for Cable Television (CATV) signal runs.
- Fits RF drop cable installations.
- Connects Over-The-Air (OTA) antenna feeds to equipment.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Coax Type | RG 11 |
| Series type | 11 |
| Plenum number | 1617AP |
| Overall cable diameter (nominal) | 0.407 in (10.3 mm) |
| Conductor nominal diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Insulation color code | White |
| Shield Type | Quad Shield (F/B+F/B) |
| Shield layer 1 | Tape, Tri-Laminate (Alum+Poly+Alum), Duobond® II, 100% |
| Shield layer 2 | Braid, Aluminum, 60% |
| Shield layer 3 | Tape, Tri-Laminate (Alum+Poly+Alum), Duofoil®, 100% |
| Shield layer 4 | Braid, Aluminum, 40% |
| Bulk cable weight | 60 lbs/1000ft |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 3 Ohm/1000ft (9.8 Ohm/km) |
| Return loss | 5 - 1000 MHz: 20 dB (min. structural return loss) |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.60 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 4.06 dB/100ft; 1000 MHz: 4.35 dB/100ft |
| Operating | -40°C to +75°C |
| UL temperature | 75°C |
| Installation min. bend radius | 4.1 in (100 mm) |
| Max Pull Tension | 308 lbs (140 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor, Aerial - Black only, When supported by messenger Wire |
| NEC / UL compliance | CM, CATV |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL1685 UL Loading |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
| Priced Per | FT |