Belden 28110A, Control Cable 3C 12 AWG PVC NYL 600V UL TC ER E2

SKU:Belden 28110A
● Em estoque
Descrição
Belden 28110A is a UL Type TC (1277) VNTC control cable with 3 conductor 12 AWG (7x20) BC - Bare Copper conductors and PVC/Nylon - Polyvinyl Chloride + Nylon insulation. It is rated 600 V (TC-ER) and 150 V (NPLF), with UL temperature ratings of 90°C dry and 90°C wet. This unshielded cable uses a black PVC - Polyvinyl Chloride outer jacket and includes a ripcord for easier jacket removal. It is listed for indoor, outdoor, sunlight resistance, and burial environments, including DIR BUR and SUN RES markings.
Belden 28110A Key Features
- UL Type TC (1277) VNTC control cable construction for power and control applications up to 600 V.
- 3 conductor 12 AWG (7x20) stranded BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation.
- Unshielded design with no ground wires.
- Black PVC - Polyvinyl Chloride outer jacket with a ripcord for easier jacket removal.
- UL voltage rating: 600 V (TC-ER), 150 V (NPLF).
- UL temperature: 90°C dry, 90°C wet; operating temperature: wet/dry: -30°C to 90°C.
- Environmental suitability: indoor, outdoor, sunlight resistance, burial; sun resistance: SUN RES; direct burial: DIR BUR.
Belden 28110A Technical Specs
Construction & Materials
| Product type | VNTC control |
|---|---|
| Conductor type | Stranded |
| Color code | Black, Red, Blue |
| Armor | No |
| Composite | No |
Dimensions & Weight
| Insulation nominal thickness | 0.022 in (0.56 mm) |
|---|---|
| Insulation nominal diameter | 0.134 in (3.40 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.382 in (9.70 mm) |
| Bulk cable weight | 103 lbs/1000ft |
Electrical Characteristics
| Nom. conductor DCR | 1.68 Ohm/1000ft |
|---|---|
| Max. current | 30 Amps per Conductor at 30ºC |
Mechanical Ratings
| Bend radius (stationary min.) | 1.52 in (38.6 mm) |
|---|---|
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max. pull tension | 260.4 lbs (118.1 kg) |
Compliance & Certifications
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
|---|---|
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER, THWN-2 Singles |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2) |
Belden 28110A Applications
- Use in power and control applications up to 600 V where a UL Type TC (1277) VNTC control cable is required.
- Specify for Class 1 Division 2 hazardous locations.
- Select Belden BTC075A0551RA as the recommended cable gland.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Product type | VNTC control |
| Conductor Type | Stranded |
| Color Code | Black, Red, Blue |
| Armor | No |
| Composite | No |
| Insulation nominal thickness | 0.022 in (0.56 mm) |
| Insulation nominal diameter | 0.134 in (3.40 mm) |
| Outer jacket nominal thickness | 0.047 in (1.2 mm) |
| Outer jacket nominal diameter | 0.382 in (9.70 mm) |
| Bulk cable weight | 103 lbs/1000ft |
| Nom. conductor DCR | 1.68 Ohm/1000ft |
| Max. current | 30 Amps per Conductor at 30ºC |
| Bend radius (stationary min.) | 1.52 in (38.6 mm) |
| Bend radius (installation min.) | 1.9 in (48 mm) |
| Max Pull Tension | 260.4 lbs (118.1 kg) |
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC-ER, THWN-2 Singles |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2) |
| Priced Per | FT |