Belden 28141A, Control Cable 5C 10 AWG PVC NYL 600V

SKU:Belden 28141A
● Em estoque
Descrição
Belden 28141A is a VNTC control cable designed for power and control applications up to 600V, including Class 1 Division 2 hazardous locations. It is built with 5 stranded 10 AWG (7x18) BC - Bare Copper conductors with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and a black PVC - Polyvinyl Chloride outer jacket. This unshielded cable includes a ripcord and is rated 90°C Dry, 90°C Wet with TC-ER marking. It is listed for indoor and outdoor use with sunlight resistance, UV resistance, and burial suitability.
Belden 28141A Key Features
- Supports power and control applications up to 600V, including Class 1 Division 2 hazardous locations.
- Built with 5 stranded 10 AWG (7x18) BC - Bare Copper conductors for control and power wiring needs.
- Uses PVC/Nylon - Polyvinyl Chloride + Nylon insulation with an E2 color code (Black, Red, Blue, Orange, Yellow) for identification.
- Unshielded construction (No Shield) with a black PVC - Polyvinyl Chloride outer jacket.
- Rated 90°C Dry, 90°C Wet and marked TC-ER.
- Includes a ripcord for easier jacket removal during installation.
- Environmental suitability includes indoor, outdoor, sunlight resistance, UV resistance, and burial.
Belden 28141A Technical Specs
Electrical & Performance Characteristics
| Nom. conductor DCR | 1.06 Ohm/1000ft |
|---|---|
| Max. current | 32 Amps per Conductor at 30ºC |
Construction & Physical Specs
| UL type | TC (1277) PVC-Nylon/PVC |
|---|---|
| Product type | VNTC control |
| Earth/ground wires | No |
| Nom. thickness (insulation) | 0.024 in (0.61 mm) |
| Nom. insulation diameter | 0.164 in (4.17 mm) |
| Nom. thickness (jacket) | 0.063 in (1.6 mm) |
| Nom. diameter (jacket) | 0.569 in (14.5 mm) |
| Overall cable diameter (nominal) | 0.569 in (14.5 mm) |
| Armor | No |
| Composite | No |
| Bulk cable weight | 257 lbs/1000ft |
Environmental & Mechanical Ratings
| Operating temperature | Wet/Dry: -30°C to 90°C |
|---|---|
| Bend radius (stationary min.) | 2.276 in (57.81 mm) |
| Bend radius (installation min.) | 2.845 in (72.26 mm) |
| Max. pull tension | 740 lbs (340 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| Marking | 600V TC-ER 90C Dry/Wet SUN RES DIR BUR |
Compliance & Certifications
| NEC / UL compliance | Article 336, Article 310, TC-ER, THWN-2 |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 28141A Applications
- Use it for power and control applications up to 600V.
- Install it in Class 1 Division 2 hazardous locations.
- Recommended cable gland: Belden BTC075A0791RA.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Nom. conductor DCR | 1.06 Ohm/1000ft |
| Max. current | 32 Amps per Conductor at 30ºC |
| UL type | TC (1277) PVC-Nylon/PVC |
| Product type | VNTC control |
| Earth/ground wires | No |
| Nom. thickness (insulation) | 0.024 in (0.61 mm) |
| Nom. insulation diameter | 0.164 in (4.17 mm) |
| Nom. thickness (jacket) | 0.063 in (1.6 mm) |
| Nom. diameter (jacket) | 0.569 in (14.5 mm) |
| Overall cable diameter (nominal) | 0.569 in (14.5 mm) |
| Armor | No |
| Composite | No |
| Bulk cable weight | 257 lbs/1000ft |
| Operating temperature | Wet/Dry: -30°C to 90°C |
| Bend radius (stationary min.) | 2.276 in (57.81 mm) |
| Bend radius (installation min.) | 2.845 in (72.26 mm) |
| Max Pull Tension | 740 lbs (340 kg) |
| Flammability / reaction to fire | UL 1685 UL Loading, IEEE 1202 FT4 |
| Marking | 600V TC-ER 90C Dry/Wet SUN RES DIR BUR |
| NEC / UL compliance | Article 336, Article 310, TC-ER, THWN-2 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.