Belden 8442 060, Multi Conductor Cable 2C 22 AWG PVC

SKU:Belden 8442 060
● Em estoque
Descrição
Belden 8442 060 is a 2-conductor 22 AWG multi conductor cable with stranded (7x30) TC - Tinned Copper conductors, PVC - Polyvinyl Chloride insulation, and a PVC - Polyvinyl Chloride outer jacket. It is rated 300 V with an 80°C UL temperature rating and an operating range of -20°C to +80°C. This cable supports 2.9 Amps per conductor at 25ºC and is intended for indoor electronic and control wiring.
Belden 8442 060 Key Features
- 2-conductor 22 AWG construction with stranded (7x30) TC - Tinned Copper conductors.
- PVC - Polyvinyl Chloride insulation with a PVC - Polyvinyl Chloride outer jacket.
- UL voltage rating: 300 V.
- UL temperature: 80°C; operating: -20°C to +80°C.
- Max. current: 2.9 Amps per conductor at 25ºC.
- NEC / UL compliance: Article 800, CMG; CEC / C(UL) compliance: CMG.
Belden 8442 060 Technical Specs
Construction & Physical Specs
| Conductor material | TC - Tinned Copper |
|---|---|
| Insulation thickness (nom.) | 0.016 in (0.41 mm) |
| Insulation diameter (nom.) | 0.060 in (1.5 mm) |
| Color code | Black, Red |
| Jacket thickness (nom.) | 0.025 in (0.64 mm) |
| Overall cable diameter (nominal) | 0.170 in (4.32 mm) |
| Bulk cable weight | 14 lbs/1000ft |
| Plenum number | 88442, 82442 |
Performance & Electrical Characteristics
| Nom. conductor DCR | 17.8 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. inductance | 0.2 μH/ft (0.66 μH/m) |
Environmental & Mechanical Ratings
| Bend radius (stationary min.) | 1.7 in (43 mm) |
|---|---|
| Bend radius (installation min.) | 1.7 in (43 mm) |
| Max. pull tension | 18 lbs (8.2 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
Compliance & Certifications
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
|---|---|
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
Belden 8442 060 Applications
- Use it for low voltage analog signals (4-20ma, 0-10v, ...) in electronic and control wiring.
- Choose it for low voltage control (24v, …) where indoor control wiring is required.
- Support line level audio connections in general-purpose wiring setups with this cable.
- Run voice communications wiring in indoor environments.
- Select it for panel wiring in electronic and control applications.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Conductor Material | TC - Tinned Copper |
| Insulation thickness (nom.) | 0.016 in (0.41 mm) |
| Insulation diameter (nom.) | 0.060 in (1.5 mm) |
| Color Code | Black, Red |
| Jacket thickness (nom.) | 0.025 in (0.64 mm) |
| Overall cable diameter (nominal) | 0.170 in (4.32 mm) |
| Bulk cable weight | 14 lbs/1000ft |
| Plenum number | 88442, 82442 |
| Nom. conductor DCR | 17.8 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 30 pF/ft (98 pF/m) |
| Nom. inductance | 0.2 µH/ft (0.66 µH/m) |
| Bend radius (stationary min.) | 1.7 in (43 mm) |
| Bend radius (installation min.) | 1.7 in (43 mm) |
| Max Pull Tension | 18 lbs (8.2 kg) |
| Environmental suitability | Indoor |
| Flammability / reaction to fire | UL 1685 FT4 Loading, FT4, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.