Belden 8450 010, Multi Conductor 2C 22 AWG Shield PVC FR

SKU:Belden 8450 010
● Em estoque
Descrição
Belden 8450 010 is a 1 pair, 22 AWG twisted pair cable for low voltage signal and control wiring. It features 22 AWG solid tinned copper conductors with PP - Polypropylene insulation, plus an overall Beldfoil® tape shield with 100% coverage and a 22 AWG solid TC drain wire. The PVC - Polyvinyl Chloride jacket is intended for indoor installations where shielding is needed to reduce noise. Key ratings include UL Voltage Rating: 300 V RMS and UL temperature: 75°C.
Belden 8450 010 Key Features
- 1 pair, 22 AWG twisted pair construction for low voltage signal and control wiring.
- 22 AWG solid tinned copper conductors with PP - Polypropylene insulation.
- Overall Beldfoil® tape shield with 100% coverage plus a 22 AWG solid TC drain wire for grounding.
- PVC - Polyvinyl Chloride jacket for indoor installations where shielding is needed to reduce noise.
- UL Voltage Rating: 300 V RMS and UL temperature: 75°C.
Belden 8450 010 Technical Specs
Construction & Materials
| Conductor stranding | Solid |
|---|---|
| Conductor material | TC - Tinned Copper |
| Insulation thickness | 0.007 in (0.18 mm) |
| Insulation color code | Black & Red |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drain wire | 22 AWG Solid TC |
| Outer jacket thickness | 0.018 in (0.46 mm) |
| Outer jacket nominal diameter | 0.118 in |
Electrical Characteristics
| Nom. conductor DCR | 16.1 Ohm/1000ft (52.8 Ohm/km) |
|---|---|
| Nom outer shield DCR | 12.65 Ohm/1000ft (41.50 Ohm/km) |
| Nom. capacitance (cond-to-cond) | 40 pF/ft (130 pF/m) |
| Nom. capacitance (cond-to-other) | 76 pF/ft (250 pF/m) |
| Nom. characteristic impedence | 40 Ohm |
| Nom. delay | 1.5 ns/ft |
| Nom. inductance | 0.08 μH/ft (0.26 μH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
Environmental & Mechanical Ratings
| Operating temperature | -20°C To +105°C |
|---|---|
| Max. pull tension | 37 lbs (17 kg) |
| Bulk cable weight | 12 lbs/1000ft (18 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| NEC / UL compliance | CM |
|---|---|
| CEC / C(UL) compliance | CM |
| NEC rating | UL Listed Art 800 |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Common uses include low voltage analog signals (4-20ma, 0-10v, ...).
- Low voltage digital control (24v, …) is supported in control and signaling circuits.
- Line level audio connections are a fit where shielding is desired.
- Computer communication wiring is also supported.
- Panel wiring in indoor installations is another typical use.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Conductor stranding | Solid |
| Conductor Material | TC - Tinned Copper |
| Insulation Thickness | 0.007 in (0.18 mm) |
| Insulation color code | Black & Red |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Shield construction | Overall Shield & drain |
| Drain Wire | 22 AWG Solid TC |
| Outer jacket thickness | 0.018 in (0.46 mm) |
| Outer jacket nominal diameter | 0.118 in |
| Nom. conductor DCR | 16.1 Ohm/1000ft (52.8 Ohm/km) |
| Nom. outer shield DCR | 12.65 Ohm/1000ft (41.50 Ohm/km) |
| Nom. capacitance cond-to-cond | 40 pF/ft (130 pF/m) |
| Nom. capacitance (Cond-to-other) | 76 pF/ft (250 pF/m) |
| Nom. characteristic impedence | 40 Ohm |
| Nom. delay | 1.5 ns/ft |
| Nom. inductance | 0.08 µH/ft (0.26 µH/m) |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
| Operating temperature | -20°C To +105°C |
| Max Pull Tension | 37 lbs (17 kg) |
| Bulk cable weight | 12 lbs/1000ft (18 kg/km) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | CM |
| CEC / C(UL) compliance | CM |
| NEC rating | UL Listed Art 800 |
| Flammability / reaction to fire | UL1685 UL Loading, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.