Belden 8451 010, Multi Conductor Twisted Pair Cable 2C 22 AWG Shield PVC

SKU:Belden 8451 010
● Em estoque
Descrição
Belden 8451 010 is a 1 pair 22 AWG twisted pair cable with a PVC - Polyvinyl Chloride jacket for low voltage signal and control wiring in Indoor - Riser applications. It uses 22 AWG stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and a paper wrap. An overall Beldfoil® shield (100% coverage) with a 22 AWG stranded TC drain wire helps reduce noise in analog signals (4-20ma, 0-10v, ...) and low voltage digital control (24v, …). It is rated 300 V and supports an operating temperature of -20°C to +75°C.
Belden 8451 010 Key Features
- 1 pair 22 AWG twisted pair construction for low voltage signal and control wiring.
- 22 AWG stranded (7x30) TC - Tinned Copper conductors with PP - Polypropylene insulation and a paper wrap.
- Overall Beldfoil® shield with 100% coverage and a 22 AWG stranded TC drain wire to help reduce noise.
- PVC - Polyvinyl Chloride jacket for Indoor - Riser, Indoor environments.
- UL voltage rating: 300 V.
- Operating temperature: -20°C to +75°C.
- Fire rating: Riser; flammability / reaction to fire: UL 1666 Riser, FT4, IEC 60332-1-2.
Belden 8451 010 Technical Specs
Construction & Materials
| Color code | Black & Red |
|---|---|
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation nominal diameter | 0.046 in (1.2 mm) |
| Shield type | Tape |
| Shield material | Bi-Laminate (Alum+Poly) |
| Jacket nominal thickness | 0.020 in (0.51 mm) |
| Jacket nominal diameter | 0.138 in (3.51 mm) |
Electrical Characteristics
| Nom. conductor DCR | 17.8 Ohm/1000ft (58.4 Ohm/km) |
|---|---|
| Nom outer shield DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. inductance | 0.17 μH/ft (0.56 μH/m) |
| Nom. inductance cond-grnd | 0.1725 μH/ft |
| Nom. delay | 1.5 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
Mechanical & Handling
| Bend radius (stationary min.) | 1.4 in (36 mm) |
|---|---|
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max. pull tension | 27 lbs (12 kg) |
| Bulk cable weight | 13 lbs/1000ft (19 kg/km) |
Environmental Suitability
| Environmental suitability | Indoor - Riser, Indoor |
|---|---|
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMR |
|---|---|
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 8451 010 Applications
- Supports low voltage analog signals (4-20ma, 0-10v, ...) where noise reduction is important.
- Handles low voltage digital control (24v, …) in control and signaling circuits.
- Performs well for line level audio signal runs.
- Fits computer communication connections that require a twisted pair and shielded design.
- Commonly used for panel wiring in indoor installations.
- Suitable for use with automatic stripping equipments.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Color Code | Black & Red |
| Insulation nominal thickness | 0.009 in (0.23 mm) |
| Insulation nominal diameter | 0.046 in (1.2 mm) |
| Shield Type | Tape |
| Shield Material | Bi-Laminate (Alum+Poly) |
| Jacket nominal thickness | 0.020 in (0.51 mm) |
| Jacket nominal diameter | 0.138 in (3.51 mm) |
| Nom. conductor DCR | 17.8 Ohm/1000ft (58.4 Ohm/km) |
| Nom. outer shield DCR | 14.1 Ohm/1000ft (46.3 Ohm/km) |
| Nom. capacitance cond-to-cond | 34 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. characteristic impedence | 45 Ohm |
| Nom. inductance | 0.17 µH/ft (0.56 µH/m) |
| Nom. inductance cond-grnd | 0.1725 µH/ft |
| Nom. delay | 1.5 ns/ft |
| Nom. velocity of prop. | 66% |
| Max. current | 2.9 Amps per Conductor at 25ºC |
| Bend radius (stationary min.) | 1.4 in (36 mm) |
| Bend radius (installation min.) | 1.4 in (36 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Bulk cable weight | 13 lbs/1000ft (19 kg/km) |
| Environmental suitability | Indoor - Riser, Indoor |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| NEC / UL compliance | Article 800, CMR |
| CEC / C(UL) compliance | CMG |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.