Belden 8473 060, Multi Pair Cable 1 Pair 14 AWG PVC PVC

SKU:Belden 8473 060
● Em estoque
Descrição
Belden 8473 060 is a 1 pair, 14 AWG multi pair cable with 14 AWG (42x30) TC - Tinned Copper stranded conductors, PVC - Polyvinyl Chloride insulation, and a PVC - Polyvinyl Chloride outer jacket. It is UL rated 600 V (CL3), 600 V (UL AWM 2587) and supports a 90°C UL temperature rating. This cable meets Article 725, CL3 requirements and is specified for indoor installations. Nominal overall diameter is 0.356 in (9.04 mm).
Belden 8473 060 Key Features
- This is a 1 pair, 14 AWG multi pair cable.
- It features 14 AWG (42x30) TC - Tinned Copper stranded conductors.
- PVC - Polyvinyl Chloride insulation includes a Black & White color code.
- A PVC - Polyvinyl Chloride outer jacket provides a nominal overall diameter of 0.356 in (9.04 mm).
- UL voltage rating is 600 V (CL3), 600 V (UL AWM 2587).
- NEC / UL compliance includes Article 725, CL3.
- Environmental suitability is indoor.
- UL temperature is 90°C.
Belden 8473 060 Technical Specs
Construction & Physical Specs
| Number of elements | 1 |
|---|---|
| Conductor size | 14 AWG |
| Stranding | 42x30 |
| Conductor material | TC - Tinned Copper |
| Conductor type | Stranded conductor |
| Insulation thickness (nom.) | 0.032 in (0.81 mm) |
| Insulation diameter (nom.) | 0.138 in (3.51 mm) |
| Jacket thickness (nom.) | 0.040 in (1.0 mm) |
| Bulk cable weight | 58 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 2.84 Ohm/1000ft |
|---|---|
| Capacitance (Cond-to-Cond) (nom.) | 22 pF/ft (72 pF/m) |
| Inductance (nom.) | 0.19 μH/ft (0.62 μH/m) |
| Max. current | 25 Amps per Conductor at 30ºC |
Environmental & Mechanical Ratings
| Operating temperature | -20°C to +90°C |
|---|---|
| Bend radius (stationary min.) | 3.6 in (91 mm) |
| Bend radius (installation min.) | 3.6 in (91 mm) |
| Max. pull tension | 106.6 lbs (48.35 kg) |
Compliance & Certifications
| AWM compliance | AWM 2587 |
|---|---|
| CEC / C(UL) compliance | FAS90 |
| Flammability / reaction to fire | UL 1685 UL loading , FT1, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 8473 060 Applications
- Use it for up to 600V analog signals in signal and control wiring.
- Support up to 600V digital control circuits where controlled signaling is required.
- Choose it for line level audio connections.
- Use it for voice communications wiring.
- Install it for panel wiring in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Number of elements | 1 |
| Conductor size | 14 AWG |
| Stranding | 42x30 |
| Conductor Material | TC - Tinned Copper |
| Conductor Type | Stranded conductor |
| Insulation thickness (nom.) | 0.032 in (0.81 mm) |
| Insulation diameter (nom.) | 0.138 in (3.51 mm) |
| Jacket thickness (nom.) | 0.040 in (1.0 mm) |
| Bulk cable weight | 58 lbs/1000ft |
| Nom. conductor DCR | 2.84 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 22 pF/ft (72 pF/m) |
| Inductance (nom.) | 0.19 µH/ft (0.62 µH/m) |
| Max. current | 25 Amps per Conductor at 30ºC |
| Operating temperature | -20°C to +90°C |
| Bend radius (stationary min.) | 3.6 in (91 mm) |
| Bend radius (installation min.) | 3.6 in (91 mm) |
| Max Pull Tension | 106.6 lbs (48.35 kg) |
| AWM compliance | AWM 2587 |
| CEC / C(UL) compliance | FAS90 |
| Flammability / reaction to fire | UL 1685 UL loading , FT1, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.