Contato1-800-975-3686
Ramcorp Wire & Cable

Belden 9155 290 1pair 20 AWG blindado TC CM Bege Claro

Belden 9155 290

SKU:Belden 9155 290

$417.60

Em estoque

Descrição

Especificações

Belden 9155 290 1pair 20 AWG blindado TC CM Bege Claro specifications
AttributeValue
Pair count1
Pair size20 AWG
Pair Stranding7x28
Pair materialTC - Tinned Copper
Conductor count2
Conductor size18 AWG
Conductor stranding19x30
Conductor MaterialTC - Tinned Copper
Conductor TypeStranded conductor
Insulation MaterialPE - Polyethylene
Pair color codeBlack & Red
Conductor color codeGreen, White
Pair shield typeTape
Pair shield materialBi-Laminate (Alum+Poly)
Drain Wire22 AWG (7x30) TC
Jacket MaterialPVC - Polyvinyl Chloride
Pair insulation thickness (nominal)0.021 in (0.53 mm)
Pair insulation diameter (nominal)0.078 in (2.0 mm)
Conductor insulation thickness (nominal)0.021 in (0.53 mm)
Conductor insulation diameter (nominal)0.085 in (2.2 mm)
Jacket thickness (nominal)0.031 in (0.79 mm)
Overall cable diameter (nominal)0.262 in (6.65 mm)
Bulk cable weight45 lbs/1000ft
Pair nominal Conductor DCR10.5 Ohm/1000ft
Pair nominal capacitance Cond-to-Cond24 pF/ft (79 pF/m)
Pair nominal capacitance (Cond-to-other)46 pF/ft (150 pF/m)
Pair nominal characteristic impedence66 Ohm
Pair nominal inductance0.195 µH/ft (0.640 µH/m)
Pair nominal velocity of prop.66%
Pair max. current7 Amps per Conductor at 25°C (20 AWG); 9 Amps per Conductor at 25°C (18 AWG)
Conductor nominal Conductor DCR6.6 Ohm/1000ft (22 Ohm/km)
Conductor nominal capacitance Cond-to-Cond22 pF/ft (72 pF/m)
Conductor nominal inductance0.173 µH/ft (0.568 µH/m)
Conductor nominal velocity of prop.66%
Conductor max. current9 Amps per Conductor @ 25°C
UL temperature60°C
Operating temperature-20°C to +60°C
Minimum bend radius (stationary)2.6 in (66 mm)
Minimum bend radius (installation)2.6 in (66 mm)
Max Pull Tension70 lbs (32 kg)
NEC / UL complianceArticle 800, CM
AWM complianceAWM 2094
CEC / C(UL) complianceCM
Flammability / reaction to fireUL 1685 UL loading , IEC 60332-1-2
CPR complianceCPR Euroclass: Eca
SustainabilityCA Prop 65
European directive complianceEU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK regulation complianceUKCA Mark
APAC complianceChina RoHS II (GB/T 26572-2011)
Item TypeBelden Multi Conductor Cable
Other Part Numbers9155 290100, 9155 290250, 9155 290500, 9155 2901000, UPC 612825224839
Priced PerFT

Documentos

As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.

Precisa de um corte sob medida, preço por volume ou uma ficha técnica?

Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.