Belden 9451P 010U, Multi Conductor 22 AWG FEP PVC Plenum

SKU:Belden 9451P 010U
● Em estoque
Descrição
Belden 9451P 010U is a line level audio cable for low voltage analog signals and control in indoor plenum spaces. It features 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors with FEP - Fluorinated Ethylene Propylene insulation and a tape shield with 100% coverage. A 22 AWG (7x30) TC drainwire is included inside the foil shield, and the jacket and shield are bonded for removal on automatic stripping equipment. Finished with a PVC - Polyvinyl Chloride jacket and CMP rating, it supports demanding fire and safety requirements.
Belden 9451P 010U Key Features
- Designed for line level audio and low voltage analog signals and control in indoor plenum spaces.
- Uses 1 pair of 22 AWG (7x30) TC - Tinned Copper conductors for consistent signal transmission.
- Includes FEP - Fluorinated Ethylene Propylene insulation with Black & Red color code for conductor identification.
- Features a tape shield with Bi-Laminate (Alum+Poly) material and 100% coverage to support noise rejection.
- Includes a 22 AWG (7x30) TC drainwire inside the foil shield to support grounding and termination.
- Has a bonded jacket and shield for removal on automatic stripping equipment.
- Finished with a PVC - Polyvinyl Chloride jacket and CMP rating for indoor plenum installations.
Belden 9451P 010U Technical Specs
Physical Construction
| Insulation thickness | 0.008 in (0.20 mm) |
|---|---|
| Insulation diameter | 0.044 in (1.1 mm) |
| Jacket thickness | 0.017 in (0.43 mm) |
| Overall diameter | 0.127 in (3.23 mm) |
| Bulk cable weight | 14 lbs/1000ft (21 kg/km) |
| Non-plenum number | 9451 |
Performance & Electrical Characteristics
| Nom. conductor DCR | 18.2 Ohm/1000ft (59.7 Ohm/km) |
|---|---|
| Nom. outer shield DCR | 13.93 Ohm/1000ft (45.70 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. inductance | 0.15 μH/ft (0.49 μH/m) |
| Nom. delay | 1.47 ns/ft |
| Nom. velocity of prop. | 69% |
| Max. current | 4.4 Amps per Conductor @ 25°C |
| UL voltage rating | 300 V (CMP) |
Environmental & Mechanical Ratings
| Operating temperature | -20°C to +75°C |
|---|---|
| UL temperature | 60°C |
| Stationary min. bend radius | 1.3 in (33 mm) |
| Installation min. bend radius | 1.3 in (33 mm) |
| Max. pull tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CMP |
|---|---|
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262 (UL910), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9451P 010U Applications
- Use it for line level audio runs where consistent signal transfer is needed in indoor plenum spaces.
- Choose it for low voltage analog signals and control connections in indoor installations.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Insulation Thickness | 0.008 in (0.20 mm) |
| Insulation Diameter | 0.044 in (1.1 mm) |
| Jacket Thickness | 0.017 in (0.43 mm) |
| Overall Diameter | 0.127 in (3.23 mm) |
| Bulk cable weight | 14 lbs/1000ft (21 kg/km) |
| Non-Plenum number | 9451 |
| Nom. conductor DCR | 18.2 Ohm/1000ft (59.7 Ohm/km) |
| Nom. outer shield DCR | 13.93 Ohm/1000ft (45.70 Ohm/km) |
| Nom. capacitance cond-to-cond | 35 pF/ft (110 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 67 pF/ft (220 pF/m) |
| Nom. inductance | 0.15 µH/ft (0.49 µH/m) |
| Nom. delay | 1.47 ns/ft |
| Nom. velocity of prop. | 69% |
| Max. current | 4.4 Amps per Conductor @ 25°C |
| UL Voltage Rating | 300 V (CMP) |
| Operating temperature | -20°C to +75°C |
| UL temperature | 60°C |
| Stationary min. bend radius | 1.3 in (33 mm) |
| Installation min. bend radius | 1.3 in (33 mm) |
| Max Pull Tension | 27 lbs (12 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| NEC / UL compliance | Article 800, CMP |
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262 (UL910), FT6, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.