Belden 9488 010, Power Limited Tray Cable 1 Pair 14 AWG 600V PVC, Black Jacket

SKU:Belden 9488 010
● Em estoque
Descrição
Belden 9488 010 is a VNTC CONTROL Power Limited Tray Cable built with 1 pair (2 conductor) 14 AWG (41x30) TC - Tinned Copper conductors and a black PVC - Polyvinyl Chloride jacket. This unshielded, twisted-pair cable uses PVC/Nylon - Polyvinyl Chloride + Nylon insulation with a Black, Red color code. It is rated 600 V (TC), 150 V (NPLF) and supports wet/dry operation from -30°C to 90°C. Designed for indoor and outdoor use, it includes sunlight resistance, burial suitability, and a ripcord for easier jacket removal.
Belden 9488 010 Key Features
- VNTC CONTROL product type with 1 pair (2 conductor) construction for instrumentation and control wiring.
- 14 AWG stranded conductors with 41x30 stranding and TC - Tinned Copper conductor material.
- Unshielded twisted-pair design with PVC/Nylon - Polyvinyl Chloride + Nylon insulation and Black, Red color code.
- Black PVC - Polyvinyl Chloride outer jacket with a ripcord for easier jacket removal.
- UL voltage rating of 600 V (TC), 150 V (NPLF).
- Environmental suitability includes indoor, outdoor, sunlight resistance, burial.
Belden 9488 010 Technical Specs
Construction & Build
| Pairs | 1 |
|---|---|
| Number of Conductors | 2 Conductor |
| Conductor Type | Stranded |
| Shield | No Shield |
| Armor | No |
| Composite | No |
| Earth/Ground Wires | No |
Physical Dimensions
| Insulation Thickness (Nom.) | 0.023 in (0.58 mm) |
|---|---|
| Insulation Diameter (Nom.) | 0.119 in (3.02 mm) |
| Jacket Thickness (Nom.) | 0.048 in (1.2 mm) |
| Overall Diameter (Nom.) | 0.359 in (9.12 mm) |
| Bulk Cable Weight | 70 lbs/1000ft |
Performance & Electrical Characteristics
| Conductor DCR (Nom.) | 2.6 Ohm/1000ft |
|---|---|
| Capacitance Cond-to-Cond (Nom.) | 50 pF/ft (160 pF/m) |
| Inductance (Nom.) | 0.24 μH/ft (0.79 μH/m) |
| Max. Current | 26 Amps per Conductor at 25ºC |
Environmental & Mechanical Ratings
| UL Temperature | 90°C Dry, 90°C Wet |
|---|---|
| Operating (Wet/Dry) | -30°C to 90°C |
| Stationary Min. Bend Radius | 1.4 in (36 mm) |
| Installation Min. Bend Radius | 1.75 in (44.5 mm) |
| Max. Pull Tension | 107 lbs (48.5 kg) |
| Flammability / Reaction to Fire | UL 1685 UL loading, IEEE 1202 FT4 |
Compliance & Certifications
| NEC / UL Compliance | Article 336, Article 760, NPLF, TC, THWN-2 |
|---|---|
| European Directive Compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC Compliance | China RoHS II (GB/T 26572-2011) |
Belden 9488 010 Applications
- Use it in industrial control systems where reliable signal and control wiring is required.
- Route it through raceways, cable trays, and ducts in industrial installations.
- Support digital control and distributed control circuits in control and instrumentation setups.
- Apply it in instrument circuits such as Instruments (4-20ma, 0-10v, ...) and low voltage digital control (24v, …).
- Specify it for encoders and other control circuits where a twisted-pair instrumentation cable is required.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Pairs | 1 |
| Number of Conductors | 2 Conductor |
| Conductor Type | Stranded |
| Shield | No Shield |
| Armor | No |
| Composite | No |
| Earth/ground wires | No |
| Insulation thickness (nom.) | 0.023 in (0.58 mm) |
| Insulation diameter (nom.) | 0.119 in (3.02 mm) |
| Jacket thickness (nom.) | 0.048 in (1.2 mm) |
| Overall diameter (Nom.) | 0.359 in (9.12 mm) |
| Bulk cable weight | 70 lbs/1000ft |
| Conductor DCR (nom.) | 2.6 Ohm/1000ft |
| Capacitance, Cond-to-Cond (nom.) | 50 pF/ft (160 pF/m) |
| Inductance (nom.) | 0.24 µH/ft (0.79 µH/m) |
| Max. current | 26 Amps per Conductor at 25ºC |
| UL temperature | 90°C Dry, 90°C Wet |
| Operating (wet/dry) | -30°C to 90°C |
| Stationary min. bend radius | 1.4 in (36 mm) |
| Installation min. bend radius | 1.75 in (44.5 mm) |
| Max Pull Tension | 107 lbs (48.5 kg) |
| Flammability / reaction to fire | UL 1685 UL loading, IEEE 1202 FT4 |
| NEC / UL compliance | Article 336, Article 760, NPLF, TC, THWN-2 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.