Belden 9921 013, Hook Up Wire 1C 22 AWG Tinned Copper PVC

Descrição
Belden 9921 013 is a low temp plastic lead wire for inter-connection circuits and internal wiring in computer, electronic, and appliance equipment. This 1-conductor 22 AWG (7x30) hook up wire features a TC - Tinned Copper conductor with PVC - Polyvinyl Chloride insulation. It is rated 105°C and 300 V RMS, with a max current of 11 A for a single conductor in free air @ 30ºC. Intended for indoor environments, it meets AWM 1007, AWM 1569, and VW-1.
Belden 9921 013 Key Features
- Low temp plastic lead wire designed for inter-connection circuits and internal wiring.
- 1-conductor 22 AWG (7x30) with TC - Tinned Copper for internal wiring connections.
- PVC - Polyvinyl Chloride insulation for indoor use.
- Rated 105°C and 300 V RMS.
- Max current: single conductor in free air @ 30ºC: 11 A.
- Compliance includes AWM 1007, AWM 1569, and VW-1 flammability.
Belden 9921 013 Technical Specs
Electrical & Physical Specs
| Number of conductors | 1 |
|---|---|
| Conductor size | 22 AWG |
| Stranding | 7x30 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.062 in (1.6 mm) |
| Nom. conductor DCR | 18.1 Ohm/1000ft |
| Bulk cable weight | 4 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. insertion loss (attenuation) | 6.2 dB/100m |
|---|---|
| Nom. insertion loss (attenuation) | 6.1 dB/100m |
| Typical unbalanced FEXT % | 6.2 MHz |
Environmental & Mechanical Ratings
| Operating temperature | -20°C To +105°C |
|---|---|
| Bend radius (stationary min.) | 0.62 in (16 mm) |
| Bend radius (installation min.) | 0.62 in (16 mm) |
| Max. pull tension | 9 lbs (4.1 kg) |
| Environmental suitability | Indoor |
Compliance & Certifications
| CEC / C(UL) compliance | TRSR-64 |
|---|---|
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Belden 9921 013 Applications
- Use it for inter-connection circuits where internal point-to-point wiring is required.
- Support internal wiring of computer and electronic equipments in indoor environments.
- Choose it for internal wiring of appliances.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Number of Conductors | 1 |
| Conductor size | 22 AWG |
| Stranding | 7x30 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PVC - Polyvinyl Chloride |
| Nom. insulation thickness | 0.017 in (0.43 mm) |
| Nom. insulation diameter | 0.062 in (1.6 mm) |
| Overall cable diameter (nominal) | 0.062 in (1.6 mm) |
| Nom. conductor DCR | 18.1 Ohm/1000ft |
| Bulk cable weight | 4 lbs/1000ft |
| Nom. insertion loss (attenuation) | 6.2 dB/100m; 6.1 dB/100m |
| Typical unbalanced FEXT % | 6.2 MHz |
| Operating temperature | -20°C To +105°C |
| Bend radius (stationary min.) | 0.62 in (16 mm) |
| Bend radius (installation min.) | 0.62 in (16 mm) |
| Max Pull Tension | 9 lbs (4.1 kg) |
| Environmental suitability | Indoor |
| CEC / C(UL) compliance | TRSR-64 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.