Belden 9925 060, 24 AWG 3C Shielded PVC Jacket Cable

Descrição
Belden 9925 060 is a Computer EIA RS-232/423 Cable for computer communications and low voltage signal transmission. It features 3 x 24 AWG Stranded (7x32) Tinned Copper Conductors with Datalene® Insulation, along with an overall Beldfoil® Shield (100% coverage) and a Tinned Copper braid (65% coverage) for noise rejection. A 24 AWG (7x32) TC Drain Wire supports termination, and the PVC Jacket provides indoor protection. UL Voltage Rating is 300 V (CM), 30 V (UL AWM 2919).
Belden 9925 060 Key Features
- 3 x 24 AWG Stranded (7x32) Tinned Copper Conductors for computer communications and low voltage signal transmission.
- Datalene® Insulation on the conductors.
- Overall Beldfoil® Shield (100% coverage) plus a Tinned Copper braid (65% coverage) for noise rejection.
- 24 AWG (7x32) TC Drain Wire for easier termination.
- PVC Jacket for indoor protection.
- UL Voltage Rating: 300 V (CM), 30 V (UL AWM 2919).
Belden 9925 060 Technical Specs
Construction & Materials
| Number of conductors | 3 |
|---|---|
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor material | TC - Tinned Copper |
| Insulation material | PE - Polyethylene (Foam) |
| Insulation thickness (nominal) | 0.013 in (0.33 mm) |
| Insulation diameter (nominal) | 0.049 in (1.2 mm) |
| Conductor color code | Black, White, Red |
| Shield tape material | Bi-Laminate (Alum+Poly) |
| Braid material | Tinned Copper (TC) |
| Jacket material | PVC - Polyvinyl Chloride |
| Jacket thickness (nominal) | 0.035 in (0.89 mm) |
Physical Dimensions & Weight
| Cable diameter (nominal) | 0.200 in (5.08 mm) |
|---|---|
| Bulk cable weight | 24 lbs/1000ft |
Performance & Electrical Characteristics
| Nom. conductor DCR | 24 Ohm/1000ft |
|---|---|
| Nom. capacitance cond-to-cond | 12 pF/ft (39 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 2.2 Amps per Conductor at 25ºC |
| Nom outer shield DCR | 5.18 Ohm/1000ft (17.0 Ohm/km) |
Environmental & Mechanical Ratings
| UL temperature | 60°C (UL CM);80°C (UL AWM 2464) |
|---|---|
| Operating temperature | -30°C to +80°C |
| Bend radius (stationary min.) | 2.4 in (61 mm) |
| Bend radius (installation min.) | 2.4 in (61 mm) |
| Max. pull tension | 44.3 lbs (20.1 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
Compliance & Certifications
| NEC / UL compliance | Article 800, CM |
|---|---|
| AWM compliance | AWM 2919 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Belden 9925 060 Applications
- Supports RS-232 Extended Distance & RS-423 Applications where reliable signal transmission is needed.
- Use it for computer communications links that require consistent data transfer.
- Handles low voltage analog signals (4-20mA, 0-10V, ...) in control and instrumentation signal paths.
- Suitable for low voltage digital control (24V, …) connections in automation and control wiring.
- Works for line level audio signal runs where shielding is beneficial.
- Fits panel wiring installations for organized internal equipment and control panel connections.
Belden™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Number of Conductors | 3 |
| Conductor size | 24 AWG |
| Conductor stranding | 7x32 |
| Conductor Material | TC - Tinned Copper |
| Insulation Material | PE - Polyethylene (Foam) |
| Insulation thickness (nominal) | 0.013 in (0.33 mm) |
| Insulation diameter (nominal) | 0.049 in (1.2 mm) |
| Conductor color code | Black, White, Red |
| Shield tape material | Bi-Laminate (Alum+Poly) |
| Braid material | Tinned Copper (TC) |
| Jacket Material | PVC - Polyvinyl Chloride |
| Jacket thickness (nominal) | 0.035 in (0.89 mm) |
| Cable diameter (nominal) | 0.200 in (5.08 mm) |
| Bulk cable weight | 24 lbs/1000ft |
| Nom. conductor DCR | 24 Ohm/1000ft |
| Nom. capacitance cond-to-cond | 12 pF/ft (39 pF/m) |
| Nom. capacitance cond-to-other (conds + Shield) | 22 pF/ft (72 pF/m) |
| Nom. velocity of prop. | 78% |
| Max. current | 2.2 Amps per Conductor at 25ºC |
| Nom. outer shield DCR | 5.18 Ohm/1000ft (17.0 Ohm/km) |
| UL temperature | 60°C (UL CM);80°C (UL AWM 2464) |
| Operating temperature | -30°C to +80°C |
| Bend radius (stationary min.) | 2.4 in (61 mm) |
| Bend radius (installation min.) | 2.4 in (61 mm) |
| Max Pull Tension | 44.3 lbs (20.1 kg) |
| Environmental suitability | Indoor (Not Riser or Plenum), Indoor |
| NEC / UL compliance | Article 800, CM |
| AWM compliance | AWM 2919 |
| CEC / C(UL) compliance | CM |
| Flammability / reaction to fire | UL 1685 UL loading , IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.