Belden BAV 1525A 010, Coax CATV Cable 14 AWG SH LDPE Black

SKU:Belden 1525A 010
● Em estoque
Descrição
Belden BAV 1525A 010 is a Series 11 broadband coax cable (RG 11) built with a 14 AWG solid BCCS - Bare Copper Covered Steel conductor and PE - Polyethylene (Foam) insulation. It uses a dual-layer shield system combining Duobond® II tri-laminate tape (100%) with a 60% aluminum braid, and it is waterblocked with grease. This 75 Ohm coax is rated 300 V and is specified for Outdoor - Water Exposure, Outdoor, UV Resistance, Aerial - When supported by messenger Wire, and Burial environments.
Key Features
- Series 11 broadband coax cable (RG 11) for CATV, RF drop cable, and Over-The-Air (OTA) antenna connections.
- 14 AWG solid BCCS - Bare Copper Covered Steel conductor.
- PE - Polyethylene (Foam) insulation with White color code.
- Dual-layer shielding: Duobond® II tri-laminate tape (Alum+Poly+Alum) at 100% coverage plus 60% aluminum braid.
- Waterblocking: Grease.
- 75 Ohm nominal characteristic impedance; voltage rating: 300 V.
- Environmental suitability: Outdoor - Water Exposure, Outdoor, UV Resistance, Aerial - When supported by messenger Wire, Burial.
Technical Specs
Physical Construction
| Overall cable diameter (nominal) | 0.393 in (9.98 mm) |
|---|---|
| Conductor nom. diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Jacket material | PE - Polyethylene |
| Bulk cable weight | 44 lbs/1000ft (65 kg/km) |
Electrical Characteristics
| Nom. velocity of prop. | 83% |
|---|---|
| Nom. capacitance cond-to-shield | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
Performance
| Return loss frequency | 5 - 1000 MHz |
|---|---|
| Min. structural return loss | 20 dB |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.47 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 3.84 dB/100ft; 1000 MHz: 4.35 dB/100ft |
Environmental & Mechanical Ratings
| Operating temperature | -55°C to +80°C |
|---|---|
| Bend radius (installation min.) | 4.5 in (110 mm) |
| Max. pull tension | 199 lbs (90.3 kg) |
Compliance & Certifications
| Other standard compliance(s) | ANSI/SCTE 74 |
|---|---|
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Use in broadband installations that require consistent coax performance across common RF frequencies.
- Support Cable Television (CATV) connections in residential or commercial distribution runs.
- Run RF drop cable to connect service entry points to equipment locations.
- Connect Over-The-Air (OTA) antennas to receiving equipment using a 75 Ohm coax connection.
Belden BAV™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Overall cable diameter (nominal) | 0.393 in (9.98 mm) |
| Conductor nom. diameter | 0.064 in |
| Nom. insulation diameter | 0.280 in (7.11 mm) |
| Jacket Material | PE - Polyethylene |
| Bulk cable weight | 44 lbs/1000ft (65 kg/km) |
| Nom. velocity of prop. | 83% |
| Nom. capacitance (Cond-to-Shield) | 16.3 pF/ft (53.5 pF/m) |
| Nom. conductor DCR | 12 Ohm/1000ft |
| Nom. outer shield DCR | 4.1 Ohm/1000ft (13 Ohm/km) |
| Return loss frequency | 5 - 1000 MHz |
| Min. structural return loss | 20 dB |
| Attenuation (Max.) | 5 MHz: 0.38 dB/100ft; 55 MHz: 0.96 dB/100ft; 211 MHz: 1.90 dB/100ft; 250 MHz: 2.05 dB/100ft; 270 MHz: 2.13 dB/100ft; 300 MHz: 2.25 dB/100ft; 330 MHz: 2.35 dB/100ft; 350 MHz: 2.42 dB/100ft; 400 MHz: 2.47 dB/100ft; 450 MHz: 2.75 dB/100ft; 500 MHz: 2.90 dB/100ft; 550 MHz: 3.04 dB/100ft; 600 MHz: 3.18 dB/100ft; 750 MHz: 3.65 dB/100ft; 870 MHz: 3.84 dB/100ft; 1000 MHz: 4.35 dB/100ft |
| Operating temperature | -55°C to +80°C |
| Bend radius (installation min.) | 4.5 in (110 mm) |
| Max Pull Tension | 199 lbs (90.3 kg) |
| Other standard compliance(s) | ANSI/SCTE 74 |
| Sustainability | CA Prop 65 |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.