Belden BAV 1855P 007, Coax Sub Miniature Plenum 23 AWG FFEP SH

SKU:Belden 1855P 007
● Em estoque
Descrição
Belden BAV 1855P 007 is a 75 Ohm SDI coax in a Mini RG-59 (Mini 59) format for high-performance digital video, including 6 Gb/s UHDTV and HD-SDI 1080p. It features a 23 AWG solid BC - Bare Copper conductor with FEP - Fluorinated Ethylene Propylene (Foam) insulation and a PVC - Polyvinyl Chloride jacket. Shielding uses braid over foil, combining Duofoil® 100% tape with a 95% Tinned Copper (TC) braid. The jacket is CMP Plenum rated with a UL Voltage Rating of 300 V (CMP).
Key Features
- This 75 Ohm SDI coax supports high-performance digital video, including 6 Gb/s UHDTV and HD-SDI 1080p.
- It uses a Mini RG-59 (Mini 59) format with coax type: RG 59.
- The conductor is 23 AWG solid BC - Bare Copper.
- Shield type is both, braid over foil, using Duofoil® 100% tape plus a 95% Tinned Copper (TC) braid.
- The PVC - Polyvinyl Chloride jacket has fire rating: Plenum and NEC / UL compliance: CMP.
Technical Specs
Construction & Physical Specs
| Coax construction | Coaxial |
|---|---|
| Overall Cable Diameter (nominal) | 0.159 in (4.04 mm) |
| Flooded | No, not flooded over braid |
| Conductor diameter (nom.) | 0.023 in |
| Insulation material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Dielectric material | FFEP-foamed (cellular) |
| Nom. Insulation Diameter | 0.102 in (2.59 mm) |
| Color code | White |
| Outer Shield layer 1 | Tape |
| Outer Shield layer 1 material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield layer 1 coverage | 100% |
| Outer Shield layer 2 | Braid |
| Outer Shield layer 2 coverage | 95% |
| Jacket Material | Flamarrest |
| Outdoor | No, not outdoor grade material |
| Bulk Cable Weight | 21 lbs/1000ft |
| Non-Plenum number | 1855A |
Electrical Characteristics
| Nom. velocity of prop. | 80% |
|---|---|
| Nom. capacitance Cond-to-Shield | 16.6 pF/ft (54.5 pF/m) |
| Nom. Conductor DCR | 20.1 Ohm/1000ft |
| Nom. outer Shield DCR | 3.7 Ohm/1000ft (12 Ohm/km) |
Signal Performance (Return Loss & Attenuation)
| Return Loss 5 - 1600 MHz | 23 dB |
|---|---|
| Return Loss 1600 - 4500 MHz | 21 dB |
| Return Loss 4500 - 6000 MHz | 15 dB |
| Attenuation (Nominal) 1 MHz | 0.38 dB/100ft |
| Attenuation (Nominal) 3.58 MHz | 0.76 dB/100ft |
| Attenuation (Nominal) 10 MHz | 1.3 dB/100ft |
| Attenuation (Nominal) 71.5 MHz | 3.1 dB/100ft |
| Attenuation (Nominal) 135 MHz | 4.1 dB/100ft |
| Attenuation (Nominal) 270 MHz | 5.8 dB/100ft |
| Attenuation (Nominal) 360 MHz | 6.9 dB/100ft |
| Attenuation (Nominal) 540 MHz | 8.7 dB/100ft |
| Attenuation (Nominal) 720 MHz | 10.3 dB/100ft |
| Attenuation (Nominal) 750 MHz | 10.5 dB/100ft |
| Attenuation (Nominal) 1000 MHz | 12.4 dB/100ft |
| Attenuation (Nominal) 1500 MHz | 15.7 dB/100ft |
| Attenuation (Nominal) 2250 MHz | 19.9 dB/100ft |
| Attenuation (Nominal) 3000 MHz | 23.8 dB/100ft |
| Attenuation (Nominal) 4500 MHz | 30.3 dB/100ft |
| Attenuation (Nominal) 6000 MHz | 36.4 dB/100ft |
Environmental & Mechanical Ratings
| UL temperature | 75°C |
|---|---|
| Operating | 0°C to +75°C |
| Installation min. Bend Radius | 4 in (100 mm) |
| Max. pull tension | 40 lbs (18 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| CEC / C(UL) compliance | CMP |
|---|---|
| Flammability / reaction to fire | NFPA 262 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
Applications
- Use in digital video installations where SDI coax is required.
- Support 6 Gb/s UHDTV signal runs in indoor environments.
- Enable HD-SDI 1080p video connections for broadcast and AV signal distribution.
Belden BAV™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Coax construction | Coaxial |
| Overall cable diameter (nominal) | 0.159 in (4.04 mm) |
| Flooded | No, not flooded over braid |
| Conductor diameter (nom.) | 0.023 in |
| Insulation Material | FEP - Fluorinated Ethylene Propylene (Foam) |
| Dielectric Material | FFEP-foamed (cellular) |
| Nom. insulation diameter | 0.102 in (2.59 mm) |
| Color Code | White |
| Outer shield layer 1 | Tape |
| Outer Shield layer 1 material | Tri-Laminate (Alum+Poly+Alum) |
| Outer Shield layer 1 coverage | 100% |
| Outer shield layer 2 | Braid |
| Outer Shield layer 2 coverage | 95% |
| Jacket Material | Flamarrest |
| Outdoor | No, not outdoor grade material |
| Bulk cable weight | 21 lbs/1000ft |
| Non-Plenum number | 1855A |
| Nom. velocity of prop. | 80% |
| Nom. capacitance (Cond-to-Shield) | 16.6 pF/ft (54.5 pF/m) |
| Nom. conductor DCR | 20.1 Ohm/1000ft |
| Nom. outer shield DCR | 3.7 Ohm/1000ft (12 Ohm/km) |
| Return loss (5 - 1600 MHz) | 23 dB |
| Return loss (1600 - 4500 MHz) | 21 dB |
| Return loss (4500 - 6000 MHz) | 15 dB |
| Attenuation (nominal) 1 MHz | 0.38 dB/100ft |
| Attenuation (Nominal) 3.58 MHz | 0.76 dB/100ft |
| Attenuation (nominal) 10 MHz | 1.3 dB/100ft |
| Attenuation (Nominal) 71.5 MHz | 3.1 dB/100ft |
| Attenuation (Nominal) 135 MHz | 4.1 dB/100ft |
| Attenuation (Nominal) 270 MHz | 5.8 dB/100ft |
| Attenuation (Nominal) 360 MHz | 6.9 dB/100ft |
| Attenuation (Nominal) 540 MHz | 8.7 dB/100ft |
| Attenuation (Nominal) 720 MHz | 10.3 dB/100ft |
| Attenuation (Nominal) 750 MHz | 10.5 dB/100ft |
| Attenuation (nominal) 1000 MHz | 12.4 dB/100ft |
| Attenuation (Nominal) 1500 MHz | 15.7 dB/100ft |
| Attenuation (Nominal) 2250 MHz | 19.9 dB/100ft |
| Attenuation (Nominal) @ 3000 MHz | 23.8 dB/100ft |
| Attenuation (Nominal) 4500 MHz | 30.3 dB/100ft |
| Attenuation (Nominal) 6000 MHz | 36.4 dB/100ft |
| UL temperature | 75°C |
| Operating | 0°C to +75°C |
| Installation min. bend radius | 4 in (100 mm) |
| Max Pull Tension | 40 lbs (18 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| CEC / C(UL) compliance | CMP |
| Flammability / reaction to fire | NFPA 262 |
| CPR compliance | CPR Euroclass: Eca; CPR UKCA Class: Eca |
| European directive compliance | EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Sustainability | CA Prop 65 |
| Priced Per | FT |