Belden BAV 1861A D26, Speaker Cable 14 AWG TW PR Black Natural

SKU:Belden 1861A D26
● Em estoque
Descrição
Belden BAV 1861A D26 is a 2 conductor speaker cable built with 14 AWG stranded BC - Bare Copper (High Conductivity) conductors and Flamarrest® Insulation. Designed for Indoor - Plenum, Indoor environments, it meets CL2P requirements and fire safety standards including NFPA 262. This cable is rated 150 V RMS and supports installation handling with a max. pull tension of 95 lbs (43 kg).
Technical Specs
Construction & Physical Specs
| Number of conductors | 2 Conductor |
|---|---|
| Conductor size | 14 AWG |
| Conductor stranding | 19x27 |
| Conductor material | BC - Bare Copper (High Conductivity) |
| Insulation | Flamarrest® Insulation |
| Insulation material | PVC - Polyvinyl Chloride |
| Shield | No Shield |
| Cabling | Open twisted construction |
| Outer jacket nominal diameter | 0.236 in |
| Bulk cable weight | 33 lbs/1000ft (49 kg/km) |
Electrical Characteristics
| UL voltage rating | 150 V RMS |
|---|
Environmental & Mechanical Ratings
| Operating temperature | -20°C To +75°C |
|---|---|
| Max. pull tension | 95 lbs (43 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
Compliance & Certifications
| NEC / UL compliance | CL2P |
|---|---|
| Flammability / reaction to fire | NFPA 262, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
Applications
- Used for speaker cable installations.
Belden BAV™ and all associated trademarks are the property of their respective owners.
Especificações
| Attribute | Value |
|---|---|
| Number of Conductors | 2 Conductor |
| Conductor size | 14 AWG |
| Conductor stranding | 19x27 |
| Conductor Material | BC - Bare Copper (High Conductivity) |
| Insulation | Flamarrest® Insulation |
| Insulation Material | PVC - Polyvinyl Chloride |
| Shield | No Shield |
| Cabling | Open twisted construction |
| Outer jacket nominal diameter | 0.236 in |
| Bulk cable weight | 33 lbs/1000ft (49 kg/km) |
| UL Voltage Rating | 150 V RMS |
| Operating temperature | -20°C To +75°C |
| Max Pull Tension | 95 lbs (43 kg) |
| Environmental suitability | Indoor - Plenum, Indoor |
| NEC / UL compliance | CL2P |
| Flammability / reaction to fire | NFPA 262, IEC 60332-1-2 |
| CPR compliance | CPR Euroclass: Eca |
| European directive compliance | EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) |
| UK regulation compliance | UKCA Mark |
| APAC compliance | China RoHS II (GB/T 26572-2011) |
| Priced Per | FT |
As imagens são apenas para referência. As especificações podem mudar sem aviso — verifique a adequação à sua aplicação antes de comprar. A documentação do fabricante prevalece.
Precisa de um corte sob medida, preço por volume ou uma ficha técnica?
Nossa equipe cotiza comprimentos personalizados e pedidos por volume, normalmente no mesmo dia.