1 Pair AWG 22 Shielded Plenum HVAC 1000 Feet

SKU:25160PV
● In stock
Description
25160PV 1 pair AWG 22 shielded plenum HVAC cable is supplied in a 1000 Feet length. This cable has 2 conductors (twisted pair), an Overall Foil Shield & Drain Wire, and a Plenum Rated Jacket. It is specified at 12.5pf/FT capacitance. Color options are Green or Orange.
1 Pair 22 AWG Shielded Plenum HVAC Applications
- Used for HVAC temperature control in building automation installations.
- Also referenced as AUTOMATED LOGIC® ARC 156 cable or Bacnet® in control and automation systems.
Frequently Asked Questions
Is 22 AWG shielded plenum HVAC cable the right choice for BACnet temperature control wiring in a plenum space?
22 AWG shielded plenum HVAC cable is a strong fit for BACnet temperature control wiring installed in plenum areas. Its twisted 22 AWG stranded tinned copper pair includes an overall foil shield, drain wire, and a plenum-rated jacket, and it is referenced for Bacnet and building automation use. That combination protects low-voltage signals from interference and lets installers route the cable above ceilings without changing to a different cable type.
Will a 1 pair 22 AWG shielded HVAC cable 1000 feet work as a replacement for Automated Logic ARC 156 cable?
1 pair 22 AWG shielded HVAC cable 1000 feet can serve that role because it is referenced as AUTOMATED LOGIC ARC 156 cable. The construction uses a single twisted pair with shielding, a drain wire, and 22 AWG stranded tinned copper conductors, which suits low-voltage automation communication and control links. That makes substitutions more straightforward and reduces the chance of mixing incompatible cable styles on control projects.
When should I choose 22 AWG shielded plenum HVAC cable with an overall foil shield and drain wire for building automation systems?
25160PV HVAC cable is the right choice when building automation wiring runs through air-handling spaces or passes near electrical noise sources. The foil shield wraps the pair to block external interference, while the drain wire provides a practical grounding path for cleaner termination and more consistent performance. This setup reduces nuisance communication issues and simplifies shield bonding at controllers, panels, and field devices.
Is 12.5 pF/ft capacitance low enough for BACnet control and automation runs on 22 AWG shielded plenum cable?
22 AWG shielded plenum HVAC cable has 12.5 pF per foot capacitance, giving installers a defined electrical value for signal-carrying control runs. Capacitance affects how much charge the cable stores and releases along the run, so a known value is important for preserving signal shape in automation and communication circuits. That supports more predictable BACnet and control system performance over distance and helps maintain consistent system behavior.
Can 1 pair 22 AWG shielded HVAC cable be used for HVAC temperature control applications that need noise protection?
1 pair 22 AWG shielded HVAC cable 1000 feet is made for HVAC temperature control work where signal protection matters. The cable uses a twisted pair to help reject induced noise and adds an overall foil shield with a drain wire to further guard low-voltage circuits from surrounding interference. This combination improves signal stability and helps controls operate more reliably in mechanical rooms, ceiling spaces, and other electrically busy areas.
Is stranded tinned copper 22 AWG HVAC cable better for control panel terminations than bare solid conductors?
25160PV HVAC cable uses stranded tinned copper conductors, which are often preferred when control wiring needs flexibility during panel work. Stranding lets the conductor bend more easily than a solid wire, while the tin coating helps resist surface oxidation that can affect long-term connection quality in low-voltage systems. That makes routing and dressing the cable easier and supports cleaner terminations in crowded control enclosures.
Disclaimer: The information provided above is for general reference only and does not constitute professional electrical advice. Always consult a licensed electrician or qualified professional before selecting, installing, or working with electrical wire and cable products. Verify all specifications, ratings, and code compliance requirements with the manufacturer and your local authority having jurisdiction (AHJ) before purchase or installation.
Specifications
| Attribute | Value |
|---|---|
| # of Conductors | 1 Pair |
| Conductor Gauge Size | 22 AWG |
| Conductor Type | Stranded Tinned Copper |
| Insulation Material | Foam Flourocopolymer |
| Shield Type | Overall Foil Shield and Drain Wire |
| Jacket Material | Green or Orange LS PVC Jacket |
| Shield (Y N) | Yes |
| Temperature | 75°C |
| Voltage | 300 Volts |
| Approvals | (UL) Or ETL, CMP CL2P RoHs |
| O.D. (Inches Nom.) | .165 |
| Color Code | Black/ White |
| Item Type | Temperature Control Cable 22/2 |
| Weight /LBS per 1000FT | 28 |
| Strand Count | 7 |
| Impedance | 100 Ohms |
| Capacitance (pF/FT) Nom. | 12.5 |
| Outer Diameter (MM Nom.) | .417 |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.