10/2 Control Cable EPR-CPE Type TC 600V Per Foot

SKU:EPRCPE-TC-10/2
● In stock
Description
This 10/2 EPR-CPE Control Cable is a 10 AWG, 2-conductor unshielded tray cable rated 600 volts and 90°C. Built with Class B stranded tinned copper conductors, flame-retardant EPR insulation, and a sunlight-resistant CPE jacket, this Type TC cable is approved for cable trays, direct burial, and Class 1 Division 2 hazardous locations. Buy by the foot at Ramcorp Wire & Cable — 100 ft minimum order.
10/2 EPR-CPE Control Cable Key Features
- UL 1277 Type TC listed for tray cable applications
- 600V rated, XHHW-2 type conductors
- 10 AWG stranded tinned copper conductors (25 strand, Class B per ASTM B-3)
- 90°C temperature rating (dry)
- Approved for direct burial and outdoor use
- Suitable for Class 1, Division 2 hazardous locations per NEC 501 & 502
- Sunlight-resistant black CPE jacket
- Flat construction for easy routing
10/2 EPR-CPE Control Cable Technical Specs
Construction & Materials
| Number of Conductors | 2 |
|---|---|
| AWG | 10 |
| Stranding | 25 strands (Class B per ASTM B-3) |
| Conductor Material | Stranded Tinned Copper |
| Insulation Material | EPR (Ethylene Propylene Rubber) |
| Insulation Thickness | 0.030 in |
| Color Code | Black, Red |
| Jacket Material | CPE (Chlorinated Polyethylene) |
| Jacket Color | Black |
Physical Dimensions & Weight
| Overall Dimensions | 0.271 in × 0.445 in (flat) |
|---|---|
| Weight | 159 lbs/1000 ft |
Environmental & Electrical Ratings
| Voltage Rating | 600 Volts |
|---|---|
| Temperature Rating | 90°C (dry) |
| Conductor Type | XHHW-2 |
| Sunlight Resistant | Yes |
| Direct Burial | Yes |
| Outdoor Rated | Yes |
Compliance & Certifications
| UL Listing | UL 1277 Type TC |
|---|---|
| Hazardous Locations | Class 1, Division 2 per NEC 501 & 502 |
| Flame Test | VW-1 |
10/2 EPR-CPE Control Cable Applications
- Power, control, and lighting circuits in industrial facilities
- Cable tray installations per NEC Article 336
- Direct burial applications in wet or dry locations
- Class 1, Division 2 hazardous locations per NEC 501 & 502
- Outdoor installations requiring sunlight-resistant cable
- Wireways, ducts, conduit, and raceway installations
- Industrial control and automation wiring
- Signal and power distribution in manufacturing plants
Frequently Asked Questions
What is 10/2 EPR-CPE tray cable used for?
This 10/2 EPR-CPE cable is used for power, control, lighting, and signal circuits in industrial settings. It is designed for installation in cable trays, conduit, raceways, and direct burial applications.
Can this cable be direct buried?
Yes, this cable is approved and rated for direct burial in wet or dry locations. The CPE jacket provides excellent moisture, chemical, and sunlight resistance for outdoor and underground installations.
Is this cable rated for hazardous locations?
Yes, this cable is suitable for Class 1, Division 2 hazardous locations per NEC Articles 501 and 502, making it appropriate for environments with potentially flammable gases or combustible dust.
What does Type TC mean?
Type TC stands for Tray Cable. It meets UL 1277 requirements and is specifically designed for installation in cable trays, as well as wireways, ducts, conduit, and direct burial applications.
Can I buy this cable by the foot?
Yes! Simply enter the footage you need when ordering — 100 ft minimum order.
All data and dimensions are nominal and subject to industry standards. © Ramcorp Technologies LLC. All Rights Reserved.
Specifications
| Attribute | Value |
|---|---|
| # of Conductors | 2 |
| Conductor Gauge Size | 10 |
| Conductor Type | Stranded Tinned Copper |
| Insulation Material | EPR |
| Jacket Material | CPE |
| Conductor Material | Tinned Copper |
| Shield (Y N) | No |
| Temperature | 90°C |
| Voltage | 600 Volts |
| Approvals | Meets (UL) 1277 requirements for type TC |
| O.D. (Inches Nom.) | .271 x .445 |
| Color Code | Black Red |
| Item Type | Control Cable EPR-CPE Direct Burial |
| Weight /LBS per 1000FT | 159 |
| Strand Count | 25 (Class B Stranded Tinned Copper per ASTM B-3 |
| Outdoor (Y N) | Yes |
| Insulation Thickness (Inches Nom.) | 0.03 |
Documents
Images are for reference only. Specifications may change without notice — verify suitability for your application before purchase. The manufacturer's documentation controls.
Need a cut length, bulk pricing, or a spec sheet?
Our team quotes custom lengths and volume orders, usually same day.