4/0 AWG 3-Conductor Shielded EPR/PVC MV-105 Cable – 5 kV / 8 kV

Description
This 4/0 AWG 3-conductor MV-105 power cable is designed for medium-voltage power circuits up to 5 kV (133%) and 8 kV (100%) in industrial, utility, and commercial power distribution systems. The cable features EPR insulation, copper tape shielding, and a PVC outer jacket, providing dependable electrical performance and long service life in demanding environments.
The 4/0 AWG stranded copper conductors offer a balance of ampacity, flexibility, and manageable diameter, making this cable well suited for installation in open air, conduit, duct systems, or direct burial. It is approved for use in wet and dry locations and commonly specified where medium-voltage reliability and code compliance are required.
Construction Overview
- Conductor: Class B stranded, annealed copper
- Conductor Shield: Extruded semiconducting thermoset compound bonded to insulation
- Insulation: Ethylene Propylene Rubber (EPR) with semiconducting layer and copper tape shield
- Assembly: Three conductors cabled with a Class B stranded, uncoated copper grounding conductor and fillers in accordance with UL 1072; overall binder tape applied
- Overall Jacket: Sunlight-resistant PVC (Polyvinyl Chloride) meeting UL and ICEA requirements
- Shield Type: Copper tape
- Ground Wire: Included
Electrical Ratings
- Voltage Rating: 5 kV (133%) / 8 kV (100%)
- Temperature Rating: 105°C
- Ampacity: Based on three single-conductor cables in isolated conduit in air per NEC Table 310.75 (90°C conductor, 40°C ambient)
Standards & Compliance
- UL Listed Type MV-105 per UL 1072
- Meets ICEA S-93-639 and AEIC CS8
- Passes UL 1685 70,000 BTU/hr flame test
- Sizes 1/0 AWG and larger marked “For CT Use”
Applications
- Industrial power distribution systems
- Chemical plants and refineries
- Steel mills and manufacturing facilities
- Utility substations and generating stations
- Medium-voltage feeders in wet or dry locations
Disclaimer: Product specifications, dimensions, weights, and availability are provided for reference only and are subject to change without notice. Actual construction, approvals, and performance characteristics may vary by manufacturer and production run. Always verify technical requirements, code compliance, and suitability for your specific application prior to installation. Installation must be performed by qualified personnel in accordance with applicable NEC, local codes, and project specifications.